Large Animal X-ray Room Repair and Integration

ID: CC0050-SR30201 • State: Washington

Description

WSU is searching a supplier to repair and integrate our Large Animal X-ray Room 1. The current system was installed in 1996.This project will need to integrate new X-ray Generator, X-ray Tube, Collimator, and Console into an existing overhead crane system that was specially created for needs of this facility. The ability to interface with Canon CXDI-31 tethered DR system.
Background
Washington State University (WSU) is seeking a supplier to repair and integrate the Large Animal X-ray Room 1 at their Veterinary Teaching Hospital. The current system was installed in 1996, and the goal of this contract is to modernize the facility's X-ray capabilities by integrating new equipment into an existing overhead crane system designed specifically for the needs of this facility.

Work Details
The project requires the integration of a new X-ray Generator, X-ray Tube, Collimator, and Console into the existing overhead crane system. The specifications for the new system include:

- A generator capable of a minimum of 40kW and 500mA with incoming power of 220VAC, single phase.
- A console and an X-ray tube compatible with existing Trunnions made for Philips model #SRO 33100 ROT 350, serial #59426A258779, allowing direct attachment to the collimator.
- A collimator and a power supply ranging from 120VAC to 220VAC with a 24V output to integrate with the existing Philips overhead crane system.
- Provision of 80ft H.V. cables and all necessary cables associated with the X-ray tube and collimator.
- The ability to interface with Canon CXDI Tethered DR system and fabricate custom X-ray tube mounting if issues arise during installation.
- A one-year parts and service warranty is required. Installation must be completed within 30 days of issuing the purchase order.

Period of Performance
The installation of the new system must be completed within 30 days after the issuance of the purchase order.

Place of Performance
The work will be performed at Washington State University's Veterinary Teaching Hospital located in Washington State.

Overview

Opportunity ID
CC0050-SR30201
Version
1
Response Deadline
April 2, 2025 Past Due
Date Posted
March 21, 2025
Est. Value Range
Experimental
$200,000 - $500,000 (AI estimate)
Agency Distribution
High
Source
Source Notes
Source does not have a linkable page for this opportunity. To find the opportunity, go to the Source website listed above and search for the Opportunity ID.
On 3/21/25 Washington State University in Washington issued Large Animal X-ray Room Repair and Integration with ID CC0050-SR30201 due 4/1/25.

Contacts

Subscribe to find 500K+ key government decision markers

Free Trial Schedule Demo

Documents

Posted documents for Large Animal X-ray Room Repair and Integration

Additional Details

System Identifier
55225
Codes
938-95 - X-Ray Equipment Maintenance and Repair992-97 - X-Ray Equipment Testing and Calibration Services898-80 - X-Ray Machines (Diagnostic) and Accessories (Except Dental)
Counties
Adams, Asotin, Benton, Chelan, Clallam, Clark, Columbia, Cowlitz, Douglas, Ferry, Franklin, Garfield, Grant, Grays Harbor, Island, Jefferson, King, Kitsap, Kittitas, Klickitat, Lewis, Lincoln, Mason, Okanogan, Pacific, Pend Oreille, Pierce, San Juan, Skagit, Skamania, Snohomish, Spokane, Stevens, Thurston, Wahkiakum, Walla Walla, Whatcom, Whitman, Yakima

Similar Active Opportunities