Background
The University of Rhode Island (URI) is seeking a contractor to perform wireless fire alarm upgrades at the Narragansett Bay Campus. This initiative is in response to changes mandated by the Town of Narragansett. The existing fire alarm reporting system requires an upgrade to a wireless system that will directly report to the Narragansett Fire Department, while also ensuring notifications are relayed back to the URI Kingston Campus Public Safety.
Work Details
The contractor will be responsible for upgrading the fire alarm reporting system to a wireless configuration. Specific tasks include:
1. Installation of a wireless fire alarm system that interfaces with both the Narragansett Fire Department and URI Kingston Campus Public Safety.
2. Coordination for unforeseen issues related to fire alarm reporting systems, architectural elements, and electrical/network infrastructure, with allowances set at $20,000, $20,000, and $30,000 respectively.
3. Additional programming and testing as requested, with an allowance of $10,000.
4. Installation of optional items such as the King Fisher Radio Box and the Digitize Muxpad DATA Gathering Module in Herman Sheets Building.
5. Liquidated damages set at $500 per day for delays beyond substantial completion.
Period of Performance
The contract period is expected to begin in February 2025 and last approximately one year. Substantial completion is targeted for September 30, 2025, with final completion by November 30, 2025.
Place of Performance
The work will be performed at the University of Rhode Island's Narragansett Bay Campus located in Narragansett, Rhode Island.
The University of Rhode Island (URI) is seeking a contractor to perform wireless fire alarm upgrades at the Narragansett Bay Campus. This initiative is in response to changes mandated by the Town of Narragansett. The existing fire alarm reporting system requires an upgrade to a wireless system that will directly report to the Narragansett Fire Department, while also ensuring notifications are relayed back to the URI Kingston Campus Public Safety.
Work Details
The contractor will be responsible for upgrading the fire alarm reporting system to a wireless configuration. Specific tasks include:
1. Installation of a wireless fire alarm system that interfaces with both the Narragansett Fire Department and URI Kingston Campus Public Safety.
2. Coordination for unforeseen issues related to fire alarm reporting systems, architectural elements, and electrical/network infrastructure, with allowances set at $20,000, $20,000, and $30,000 respectively.
3. Additional programming and testing as requested, with an allowance of $10,000.
4. Installation of optional items such as the King Fisher Radio Box and the Digitize Muxpad DATA Gathering Module in Herman Sheets Building.
5. Liquidated damages set at $500 per day for delays beyond substantial completion.
Period of Performance
The contract period is expected to begin in February 2025 and last approximately one year. Substantial completion is targeted for September 30, 2025, with final completion by November 30, 2025.
Place of Performance
The work will be performed at the University of Rhode Island's Narragansett Bay Campus located in Narragansett, Rhode Island.
Overview
Agency
Opportunity Type
RFQ
Opportunity ID
RFQ25004990
Version
1
Response Deadline
Feb. 5, 2025
Past Due
Date Posted
Dec. 3, 2024
Est. Value Range
Experimental
$500,000 - $1,500,000
(AI estimate)
Agency Distribution
High
Source
Source Notes
Source does not have a linkable page for this opportunity. To find the opportunity, go to the Source website listed above and search for the Opportunity ID.
On 12/3/24 State of Rhode Island in Rhode Island issued RFQ URI NBC Wireless Fire Alarm Upgrades with ID RFQ25004990 due 2/5/25.
Contacts
Documents
Posted documents for URI NBC Wireless Fire Alarm Upgrades
Opportunity Assistant
AI Analysis
AI Generate
Classifications
Additional Details
Who Can Respond
All Vendors