D24AC00166
Cooperative Agreement
Overview
Grant Description
Funding opportunity number - HR001123S0052
DARPA's Microsystems Technology Office will develop compact, ultralow-noise optical detectors that employ squeezed-light measurement techniques to advance precision optical sensing.
Specifically excluded is research that primarily results in evolutionary improvements to the existing state of practice.
DARPA's Microsystems Technology Office will develop compact, ultralow-noise optical detectors that employ squeezed-light measurement techniques to advance precision optical sensing.
Specifically excluded is research that primarily results in evolutionary improvements to the existing state of practice.
Funding Goals
DEVELOP THE CENTRAL CHIP SCALE PHOTONIC DEVICES REQUIRED FOR A SQUEEZED LIGHT DETECTOR. THE TWO TEST ARTICLES FOR PHASE 1 ARE A SQUEEZED LIGHT GENERATOR WITH HIGH SR AND A PHASE SENSITIVE INTERFEROMETER CIRCUIT WITH LOW AGGREGATE OPTICAL LOSS. PHASE 1 METRICS AND REQUIREMENTS FOR EACH TEST ARTICLE AS NOTED IN TABLE 1 AND ENSUING FOOTNOTES ARE CHALLENGING IN ORDER TO DEMONSTRATE THAT CHIP SCALE PHOTONICS ARE CAPABLE OF PRODUCING AND MANIPULATING STRONGLY SQUEEZED STATES OF LIGHT. EACH CHIP SCALE TEST ARTICLE MAY BE MEASURED INDEPENDENTLY THROUGH BENCH TOP CHARACTERIZATION. IN ORDER TO ENSURE THAT THE DEVICES ARE SUITABLE FOR INTEGRATION INTO THE END OF PROGRAM PROTOTYPE MODULES PHASE 1 ALSO REQUIRES PERFORMERS TO CARRY OUT A MID PHASE PRELIMINARY DESIGN REVIEW (PDR) AND AN END OF PHASE CRITICAL DESIGN REVIEW (CDR) AS WELL AS DELIVER TEST ARTICLE HARDWARE TO DARPA FOR INDEPENDENT VERIFICATION AND VALIDATION (IV AND V). DEMONSTRATE SQUEEZED LIGHT DETECTOR PROTOTYPES WITH SENSITIVITY EXCEEDING THE QUANTUM SHOT NOISE LIMIT IN A MODULE WITH VOLUME COMPARABLE TO COMMERCIAL PHOTODETECTOR COMPONENTS. THE TEST ARTICLE FOR PHASE 2 IS THE PROTOTYPE MODULE ITSELF WHICH IS EXPECTED TO INCLUDE THE PHASE 1 TEST ARTICLES ALONG WITH ALL OTHER ANCILLARY OPTICAL AND ELECTRICAL COMPONENTS REQUIRED TO PERFORM A SQUEEZING ENHANCED MEASUREMENT. FIGURE 1 TABLE 1 AND TABLE 1 FOOTNOTES RESPECTIVELY DEFINE THE REQUIRED MODULE INPUTS AND OUTPUTS PERFORMANCE AND SIZE METRICS AND TEST CONDITIONS FOR EACH METRIC. PERFORMERS ARE EXPECTED TO DELIVER FUNCTIONAL SQUEEZED LIGHT DETECTOR PROTOTYPES THAT CAN BE CHARACTERIZED BY IV AND V GROUPS AND ASSESSED AS DETECTOR COMPONENTS WITHIN AN UNSPECIFIED OPTICAL SYSTEM.
Grant Program (CFDA)
Awarding / Funding Agency
Place of Performance
Santa Barbara,
California
United States
Geographic Scope
County-Wide
Related Opportunity
D-AQD-FA-24-017
Analysis Notes
Amendment Since initial award the total obligations have increased 718% from $667,349 to $5,459,111.
Santa Barbara University Of California was awarded
Advanced Compact Optical Detectors Precision Sensing - HR001123S0052
Cooperative Agreement D24AC00166
worth $5,459,111
from Interior Business Center in July 2024 with work to be completed primarily in California United States.
The grant
has a duration of 1 year 6 months and
was awarded through assistance program 12.910 Research and Technology Development.
Status
(Ongoing)
Last Modified 4/2/25
Period of Performance
7/15/24
Start Date
1/14/26
End Date
Funding Split
$5.5M
Federal Obligation
$0.0
Non-Federal Obligation
$5.5M
Total Obligated
Activity Timeline
Subgrant Awards
Disclosed subgrants for D24AC00166
Transaction History
Modifications to D24AC00166
Additional Detail
Award ID FAIN
D24AC00166
SAI Number
None
Award ID URI
None
Awardee Classifications
Public/State Controlled Institution Of Higher Education
Awarding Office
140D04 IBC ACQ SVCS DIRECTORATE (00004)
Funding Office
140D04 IBC ACQ SVCS DIRECTORATE (00004)
Awardee UEI
G9QBQDH39DF4
Awardee CAGE
4B561
Performance District
CA-24
Senators
Dianne Feinstein
Alejandro Padilla
Alejandro Padilla
Modified: 4/2/25