Background
The U.S. Geological Survey (USGS) is issuing a funding opportunity for a Cooperative Agreement aimed at developing a robust and reliable quantitative method to correct for solution chemistry interferences in molecularly imprinted polymer – electrochemical sensor (MIP-ES) measurements of complex environmental water matrices.
This project aligns with the administration's priority to protect human health by generating data and tools that identify potential risks to drinking water quality, thereby safeguarding communities from exposure to harmful contaminants.
Grant Details
The grant involves the development of a ratiometric comparison approach with MIP-ES, which includes:
1. Bench scale proof of concept ratiometric sensing with perfluorooctanoate (PFOA) and perfluorooctanesulfonate (PFOS) based MIP-ES.
2. Bench scale tap water ratiometric sensing with PFOA and PFOS based MIP-ES.
3. Bench scale surface water ratiometric sensing using MIP-ES to demonstrate performance in real-world environmental samples.
4. Ratiometric sensing single-blind study trials with surface water samples.
5. Deployment of MIP-ES ratiometric sensing in real-world samples sourced from Joint Base Cape Cod, MA, including high concentration PFAS sites and groundwater depth samples.
6. Data analysis will include unpaired t-tests and one-way ANOVA to evaluate statistically significant differences between ratios.
Eligibility Requirements
Eligible applicants must be participating partners of the Northern Great Plains Cooperative Ecosystem Studies Unit (CESU). There is no cost-sharing requirement for this grant.
Period of Performance
The project is expected to start on January 1, 2027, and end on December 31, 2029.
Grant Value
The total estimated funding for this project is $450,000, with an expected number of awards being one.
Place of Performance
The primary place of performance for this grant will be Joint Base Cape Cod in Cape Cod, MA.
Robust and reliable quantitative method to correct for solution chemistry interferences in molecularly imprinted polymer electrochemical sensor (MIP-ES) measurements of complex environmental water matrices
The goal of this research is to develop a robust and reliable quantitative method to correct for solution chemistry interferences in MIP-ES measurements of complex environmental water matrices. One of the challenges using MIP-ES to measure contaminants such as per- and polyfluoroalkyl substances (PFAS) in environmental samples is understanding how bulk solution chemistry contributes to the electrochemical background signal. The development of a ratiometric comparison approach with MIP-ES will involve bench scale proof of concept testing and then escalate to field deployed trials. Instrumentation required for MIP-ES fabrication and sensing includes multichannel potentiostats capable of differential pulse voltammetry and cyclic voltammetry. Differential pulse voltammetry will be used to collect current differences at 1-minute and 15-minute incubation time points in the sample matrices. These current values will be used to build the ratiometric comparison approach.
The ratiometric approach will involve the comparison of normalized current difference ratios, outlined in Equation 1, between a matrix matched solution that contains all matrix constituents minus the analyte in question and an unknown solution that is composed of the sample matrix and may or may not contain the analyte.
The use of a ratiometric comparison isolates current differences from the association of the analyte with the MIP-ES binding sites from any change in current from interferent effects due to the rest of the sample matrix constituents (i.e., humic acids, fulvic acids, ions, non-fluorinated counterparts, etc.). A ratio close to 1 indicates the absence of the analyte due to similar normalized current difference values in the ratio. A statistically different ratio from 1 indicates the presence of the analyte in question in the sample matrix.
This project supports the administration's priority to protecting human health by generating data and tools that identify potential risks to drinking water quality. By enabling early detection and informed decision-making, this work helps safeguard communities from exposure to harmful contaminants and ensures access to safe, clean drinking water.
Robust and reliable quantitative method to correct for solution chemistry interferences in molecularly imprinted polymer electrochemical sensor (MIP-ES) measurements of complex environmental water matrices
The goal of this research is to develop a robust and reliable quantitative method to correct for solution chemistry interferences in MIP-ES measurements of complex environmental water matrices. One of the challenges using MIP-ES to measure contaminants such as per- and polyfluoroalkyl substances (PFAS) in environmental samples is understanding how bulk solution chemistry contributes to the electrochemical background signal. The development of a ratiometric comparison approach with MIP-ES will involve bench scale proof of concept testing and then escalate to field deployed trials. Instrumentation required for MIP-ES fabrication and sensing includes multichannel potentiostats capable of differential pulse voltammetry and cyclic voltammetry. Differential pulse voltammetry will be used to collect current differences at 1-minute and 15-minute incubation time points in the sample matrices. These current values will be used to build the ratiometric comparison approach.
The ratiometric approach will involve the comparison of normalized current difference ratios, outlined in Equation 1, between a matrix matched solution that contains all matrix constituents minus the analyte in question and an unknown solution that is composed of the sample matrix and may or may not contain the analyte.
The use of a ratiometric comparison isolates current differences from the association of the analyte with the MIP-ES binding sites from any change in current from interferent effects due to the rest of the sample matrix constituents (i.e., humic acids, fulvic acids, ions, non-fluorinated counterparts, etc.). A ratio close to 1 indicates the absence of the analyte due to similar normalized current difference values in the ratio. A statistically different ratio from 1 indicates the presence of the analyte in question in the sample matrix.
This project supports the administration's priority to protecting human health by generating data and tools that identify potential risks to drinking water quality. By enabling early detection and informed decision-making, this work helps safeguard communities from exposure to harmful contaminants and ensures access to safe, clean drinking water.