657-27-111JB, Install Continuous Water Monitoring System,

ID: 36C25527Q0052 • Notice Type: Sources Sought • Match:  90%
Opportunity Assistant

Hello! Please let me know your questions about this opportunity. I will answer based on the available opportunity documents.

Please sign-in to link federal registration and award history to assistant. Sign in to upload a capability statement or catalogue for your company

Analyze Opportunity
Generate a Draft
Loading

Description

Background
The Department of Veterans Affairs is seeking service disabled veteran owned small business (SDVOSB) firms for a potential small business set-aside for a construction services project. This Sources Sought Notice serves as a market research tool to determine the availability of qualified contractors capable of performing the required services prior to issuing a Best Value type Request for Proposal (RFP). The project involves the installation of continuous water monitoring systems at various buildings within the Jefferson Barracks VAMC.

Work Details
The project scope includes the installation of continuous monitoring equipment for biocides, pH levels, pressure, and temperature at domestic cold water sources and hot water generation systems in VHA DIR 1061 Buildings. Additional temperature sensors will be installed at mid-points and end-of-line for each major distribution system.

The specific tasks include:
- For Building 3: Installation of monitoring equipment for incoming cold water, distal cold water points, hot water source supply and return temperatures, and mid-point temperature monitoring.
- For Building 51: Similar installations as Building 3 with additional distal cold water points.
- For Building 52: Same requirements as Building 3.
- For Building 53: Same requirements as Building 3.
- For Building 59: Same requirements as Building 3.

Additionally, full training on the new water monitoring equipment and basic instrumentation & controls (I&C) training will be provided. All contractor work must comply with VHA Directive 1061.

Place of Performance
Jefferson Barracks VAMC, St Louis, MO.

Bidder Requirements
Bidders must be service disabled veteran owned small businesses (SDVOSB) and provide evidence of their capability to perform similar contracts within the past five years. Requirements include:
- Bonding capability demonstrated by a letter from Surety indicating bonding levels per contract and aggregate.
- Contractor licensing relevant to General Construction with a business size limit of $45 million.
- Submission of a Capability Statement including company information, interest in bidding, examples of comparable work performed, CVE certification as a Veteran owned business, socio-economic status, percentage of self-performed labor, and joint venture information if applicable.
— Amendment Summary:
  • The NAICS code changed from 236220 (General Construction; $45 million size standard) to 238220 (Plumbing, Heating, and Air-Conditioning Contractors; $19 million size standard). Socioeconomic status and capability responses must now address NAICS 238220.
  • Responses submitted under NAICS 236220 will not be considered; eligible firms must resubmit under NAICS 238220. See 36C25527Q0052_1.docx.
  • The response deadline moved from November 12, 2026 at 10:00 a.m. Central to November 9, 2026 at 3:00 p.m. Central.
Government Description:
657-27-111JB, Install Continuous Water Monitoring System This modification is to correct the NAICS code to 238220 Plumbing, Heating, and Air-Conditioning Contractors. If you have submitted a response for NAICS code 236220 this response will not be considered. If eligible please resubmit under NAICS code 238220. This is a Sources Sought Notice to determine the availability of service disabled veteran owned small business (SDVOSB) firms for a possible small business category type set-aside for Construction Services project: This is a Sources Sought Notice that is issued for information and planning purposes only and is not to be construed as a commitment by the government, implied or otherwise to issue a solicitation or ultimately award a contract. An award will not be made on information received in response to this notice. This notice is not a Request for Proposal (RFP); it is a market research tool being utilized to determine the availability of sources prior to issuing a Best Value type RFP. PROJECT DESCRIPTION AND SCOPE This project will install continuous monitoring equipment for biocides, PH level, pressure and temperature at domestic cold water sources and hot water generation for VHA DIR 1061 Buildings, additional temperature sensors on the hot distribution will be installed at mid-point and end-of-line for each major distribution system of the buildings. Data will be back net capable for Building automation system (BAS) VA Johnson controls tie-in and real-time monitoring. Scope includes: JB Bldgs 3, 51, 52, 53, 59 Jefferson Barracks VAMC: Building 3: 1 incoming cold water continuous monitoring with pressure and temperature 1 cold water distal Furthest point from incoming cold water 1 hot water distal Furthest point from incoming hot water 1 hot water source equipment supply temperature 1 hot water source equipment return temperature Monitoring cold and hot temperature at midpoints at each riser Building 51: 1 incoming cold water continuous monitoring with pressure and temperature 2 cold water distal -Furthest point from incoming cold water 1 hot water distal Furthest point from incoming hot water 1 hot water source equipment supply temperature 1 hot water source equipment return temperature Monitoring cold and hot temperature at midpoints at each riser Building 52: 1 incoming cold water continuous monitoring with pressure and temperature 1 cold water distal Furthest point from incoming cold water 1 hot water distal Furthest point from incoming hot water 1 hot water source equipment supply temperature 1 hot water source equipment return temperature Monitoring cold and hot temperature at midpoints at each riser Building 53: 1 incoming cold water continuous monitoring with pressure and temperature 1 cold water distal Furthest point from incoming cold water 1 hot water distal Furthest point from incoming hot water 1 hot water source equipment supply temperature 1 hot water source equipment return temperature Monitoring cold and hot temperature at midpoints at each riser Building 59: 1 incoming cold water continuous monitoring with pressure and temperature 1 cold water distal Furthest point from incoming cold water 1 hot water distal Furthest point from incoming hot water 1 hot water source equipment supply temperature 1 hot water source equipment return temperature Monitoring cold and hot temperature at midpoints at each riser Provide full training of new water monitoring equipment and basic I&C training relating to this project. Contractor work must fully comply with VHA Directive 1061 The intent of this notice is to identify potential Small Business firms capable of performing these services. The Government will use the information obtained from this sources sought announcement to make a set-aside determination including further restriction under a socio-economic status, firms must identify their socio-economic status for NAICS code 238220 Plumbing, Heating, and Air-Conditioning Contractors. The appropriate North American Industry Classification System (NAICS) code for this acquisition is 238220 with the applicable business size of 19.0 million. If interested in this opportunity, please provide via email a Capability Statement: The Capability Statement is designed to inform the Department of Veteran Affairs, of any prospective construction contractors' project execution capabilities. The submission is limited to 10 single sided pages which shall include the following information: 1) Offeror's name, address, point of contact, phone number, e-mail address, and EIN number; 2) Offeror's interest in bidding on the solicitation when it is issued; 3) Offeror's capability to perform a contract of this magnitude and complexity and comparable work performed within the past 5 years - brief description of the project, customer name, timeliness of performance, customer satisfaction, and dollar value of the project) - provide at least 3 examples; 4) Offeror's CVE certification as a Veteran owned business; 5) Please provide Socio-economic status for NAICS code 238220 Plumbing, Heating, and Air-Conditioning Contractors and provide percentage of self-performed labor your company can perform for this type of project; 6) Offeror's Joint Venture information if applicable - existing and potential; 7) Offeror's Bonding Capability in the form of a letter from Surety providing bonding level per contract and aggregate. The Response Due Date for this Sources Sought Notice is November 12. 2026 at 10:00 am Central Time. Respondents will not be notified of the results of analysis. Submit your responses to Jennifer.Hill@va.gov. PLEASE REFERENCE "SOURCES SOUGHT: 36C25527Q0052 Project 657-27-111JB, Install Continuous Water Monitoring System" IN THE SUBJECT LINE and first page of the response. The point of contact for submission of Capabilities Statement and questions is: Jennifer Hill Contracting Officer Email: jennifer.hill@va.gov NCO 15 Contracting Office Leavenworth, Kansas 66048 No basis for claim against the Government shall arise as a result of a response to this sources sought or Government use of any information provided. The Government will not pay for information or comments provided and will not recognize any costs associated with submission of comments. There is no guarantee, expressed or implicit, that market research for this acquisition will result in a particular set-aside, or any other guarantee of award or acquisition strategy. Respondents will not be contacted regarding their submission or information gathered as a result of this Sources Sought notice. Interested firms shall be required to respond to additional announcements separately from this announcement without further notice from the Government when posted to the Contract Opportunities website at https://sam.gov/. The Contract Opportunities website is the only official site to obtain these documents.
Posted:
Loading Map
Loading Map

Overview

Response Deadline
Past Due
Original deadline:
Posted Date
Last updated:
Set Aside
Service Disabled Veteran Owned Small Business (SDVOSBC)
Place of Performance
St Louis VAMC Jefferson Barracks 1 Jefferson Barracks Drive, St. Louis, MO 63125
Source

Q&A Instructions
Submit questions to Jennifer Hill, contracting officer, at jennifer.hill@va.gov.
Estimated Contract Value
$250,000 - $750,000
Pricing Structure
Likely Fixed Price
Evaluation Criteria
Best Value
Estimated Competition Level
Low
Odds of Advancing to Solicitation
45%
Current SBA Size Standard
$19 Million
Signs of Shaping
The solicitation is open for 4 days, below average for the VISN 15: Heartland Network.
On 11/5/26 VISN 15: Heartland Network issued Sources Sought 36C25527Q0052 for 657-27-111JB, Install Continuous Water Monitoring System, due 11/9/26. The opportunity was issued with a Service Disabled Veteran Owned Small Business (SDVOSBC) set aside with NAICS 238220 (SBA Size Standard $19 Million) and PSC Z2DA.
Primary Contact
Title
Contracting Officer
Name
Jennifer Hill   Profile
Phone
(913) 946-1144

Documents

Posted documents for Sources Sought 36C25527Q0052

Opportunity Assistant


Analyze Opportunity

Generate a Draft

Incumbent or Similar Awards

Contracts Similar to Sources Sought 36C25527Q0052

Potential Bidders and Partners

Awardees that have won contracts similar to Sources Sought 36C25527Q0052

Similar Active Opportunities

Open contract opportunities similar to Sources Sought 36C25527Q0052

Experts for 657-27-111JB, Install Continuous Water Monitoring System,

Recommended subject matter experts available for hire

Additional Details

Source Agency Hierarchy
VETERANS AFFAIRS, DEPARTMENT OF > VETERANS AFFAIRS, DEPARTMENT OF > 255-NETWORK CONTRACT OFFICE 15 (36C255)
FPDS Organization Code
3600-00255
Source Organization Code
100186523
Last Updated
Last Updated By
jennifer.hill@va.gov
Archive Date
Original Title
Z2DA--657-27-111JB, Install Continuous Water Monitoring System,