657-23-101JB FCA Replace Various Air Handling Units/Chillers Buildings 1, 24 and 51   3

ID: 36C25525R0097 • Type: Solicitation • Match:  85%
Opportunity Assistant

Hello! Please let me know your questions about this opportunity. I will answer based on the available opportunity documents.

Please sign-in to link federal registration and award history to assistant. Sign in to upload a capability statement or catalogue for your company

Some suggestions:
Please summarize the work to be completed under this opportunity
I'd like to anonymously submit a question to the procurement officer(s)
Loading

Description

Posted: Aug. 5, 2025, 10:26 a.m. EDT
RFI #65. Can the morgue be shut down during construction? Providing temp cooling for that area to the degree required will be between difficult and impossible. If the shutdown is not possible, can you please provide clarification on how temp cooling for that area is to be accomplished so we can properly price this scope? Including the size and placement of temp unit/units that will achieve the appropriate temperatures? We don't use the JB morgue too often. Most patients that pass at JB go directly to the funeral home. The morgue is only used with the veteran does not have funeral home plans in place. The backup plan is the patient will be transported to JC morgue until funeral home arrangements are made. RFI #70. Sizing the temp units based on a preconstruction TAB report will not enable us to provide the proper pricing for our scope of work. This information needs to be available for us to include the correct pricing at the time of our bid not after we are awarded the project. Otherwise, it becomes and guess which usually drives the price up. AHU-01-1 Trane CSHX0035F3 (OR EQUIVALENT) (with electric heat), 7000 CFM Nominal, 5in Max ESP, 460V 3 Phase, MCA 179.8A, MOP 200A. Note: The contractor shall coordinate required electrical connection with the VA. AHU-01-2 Trane CSHX0035F3 (OR EQUIVALENT) (with electric heat), 7000 CFM Nominal, 5in Max ESP, 460V 3 Phase, MCA 179.8A, MOP 200A. Note: The contractor shall coordinate required electrical connection with the VA. AHU-24-1 Trane CSH0050F4 (OR EQUIVALENT) (with electric heat), 10000 CFM nominal, 5in Max ESP, 460V 3 Phase, MCA 232.2A, MOP 250A. Note: 460V unavailable at building 24. The contractor shall coordinate required electrical connection with the VA.. AHU-51-1 Trane RSHX0080 (OR EQUIVALENT) (with electric heat), 12,800 CFM nominal, 4.8in Max ESP, 460V 3 Phase, MCA 329A, MOP 400A Note: 460V unavailable at building 24. The contractor shall coordinate required electrical connection with the VA. If alternate is used, unit must have adequate capacity for DOAS application. The needs of the station and the temporary units are based on availability. The information provided is to ensure the contractor understands the situation and the need to ensure a maintenance team/ plan is made available by the subcontractor to avoid any issues with the temporary cooling during construction. Power can be provided to the temporary units as follows: Building 1: Feed the temporary AHU from 208V panel EMDP . Provide temporary transformer and connections as necessary. Building 24: Feed the temporary AHU from 208V External Wireway . Provide temporary transformer and connections as necessary. Building 51: Feed the temporary AHU from 208V switchboard MSB-51A . Provide temporary transformer and connections as necessary. RFI #72, 73 & 108. We need the design team to provide the proper information on the steam trap sizing and placement. Including the traps at the units and any drip traps that might be required. This is a complicated issue that would need to be designed .by the design team .not the installing contractor. Drip traps are generally based on the pounds per hour capacity of the main. This information is not available to us. Steam trap to be placed at the unit steam coil / humidifier. Anticipated piping lengths do not require steam drip traps. Contractor to verify and report the piping lengths from steam mains. STEAM TRAP SCHEDULE BASIS OF DESIGN MANUFACTURER TRAP NO. TRAP SIZE MAX PRESSURE (PSI) STEAM CONDENSATE LOAD CONSTRUCTION AHU-1-01 HEATING COIL SPIRAX SARCO FT450-4.5 1" 15 217 STAINLESS STEEL AHU-1-02 HEATING COIL SPIRAX SARCO FT450-4.5 1" 15 276 STAINLESS STEEL AHU-24-01 HEATING COIL SPIRAX SARCO FT450-4.5 1-1/2" 15 466 STAINLESS STEEL AHU-51-01 HUMIDIFER SPIRAX SARCO FT450-4.5 3/4" 15 23 STAINLESS STEEL NOTE: STEAM TRAP CONNECTION SHALL BE RAISED FACE FLANGE. Additional Information regarding RFIs 97 and 100: 3C06 As builts and site photos: Condensate pumps in basement mechanical room GC18: Location of the Steam supply and condensate return riser main connection to horizontal main. No as-built of the steam condensate pump is available in Building 1, Room GC18. The steam riser main is 2-1/2 and the condensate return riser main is 2 based on as-built drawings available as noted above.
Posted: Aug. 4, 2025, 11:01 a.m. EDT
Posted: July 24, 2025, 11:10 a.m. EDT
Posted: July 17, 2025, 4:49 p.m. EDT
Posted: July 10, 2025, 1:01 p.m. EDT
Posted: May 29, 2025, 3:54 p.m. EDT
Background
The Veterans Affairs Saint Louis Health Care System (VASTLHCS) is dedicated to providing high-quality health care to veterans. To support this mission, the Facility Engineering Service (FES) is seeking a contractor for a project aimed at replacing various air handling units and chillers in Buildings 1, 24, and 51 at the Jefferson Barracks Division in St. Louis, MO. This renovation addresses poor Facility Condition Assessments (FCA) and aims to replace obsolete mechanical equipment that has exceeded its useful life by 11-45 years.

The project is critical for improving patient care environments regarding temperature and humidity control and aligns with VHA priorities for SCIP FY2023.

Work Details
The scope of work includes the following tasks:
- Building 1: Replace two Trane Duplex AHUs serving the 3rd Floor Offices & Corridors, one Trane Simplex AHU serving the former Animal Research area, and the Morgue Refrigeration Unit. Replace condensate pumps and a vertical R-22 AHU leaking refrigerant.
- Building 24: Replace the air handling unit (AHU-01) serving the Canteen and Auditorium due to multiple leaks; replace an old exhaust fan in the mechanical room.
- Building 51: Replace an AHU serving the North side of the 1st Floor, approximately 130 FCUs operating with hot water instead of steam, and VAV boxes with hot water reheat coils. Additionally, replace old pumps and steam to hot water converters that are at the end of their useful life.

The project will also focus on reducing energy consumption and greenhouse gas emissions as per Executive Orders 13423 and 13514.

Period of Performance
The period of performance for this contract is expected to be approximately 270 calendar days after issuance of the Notice to Proceed (NTP), including mobilization, construction, final inspection, corrective work, and closeout documentation.

Place of Performance
The construction projects will be performed at Jefferson Barracks Division, St. Louis, MO.

Overview

Response Deadline
Aug. 12, 2025, 11:00 a.m. EDT (original: July 14, 2025, 11:00 a.m. EDT) Past Due
Posted
May 29, 2025, 3:54 p.m. EDT (updated: Aug. 5, 2025, 10:26 a.m. EDT)
Set Aside
None
Place of Performance
Not Provided
Source

Current SBA Size Standard
$19 Million
Pricing
Likely Fixed Price
Evaluation Criteria
Best Value
Est. Level of Competition
Average
Signs of Shaping
79% of similar contracts within the Veterans Health Administration had a set-aside.
On 5/29/25 VISN 15: Heartland Network issued Solicitation 36C25525R0097 for 657-23-101JB FCA Replace Various Air Handling Units/Chillers Buildings 1, 24 and 51 due 8/12/25. The opportunity was issued full & open with NAICS 238220 and PSC Z1DA.
Primary Contact
Title
Contract Specialist
Name
Sean P Jackson   Profile
Phone
None

Additional Contacts in Documents

Title Name Email Phone
Network Contracting Officer Jennifer Hill Profile jennifer.hill@va.gov None

Documents

Posted documents for Solicitation 36C25525R0097

Question & Answer

The AI Q&A Assistant has moved to the bottom right of the page

Opportunity Lifecycle

Procurement notices related to Solicitation 36C25525R0097

Award Notifications

Agency published notification of awards for Solicitation 36C25525R0097

Contract Awards

Prime contracts awarded through Solicitation 36C25525R0097

Incumbent or Similar Awards

Contracts Similar to Solicitation 36C25525R0097

Potential Bidders and Partners

Awardees that have won contracts similar to Solicitation 36C25525R0097

Similar Active Opportunities

Open contract opportunities similar to Solicitation 36C25525R0097

Additional Details

Source Agency Hierarchy
VETERANS AFFAIRS, DEPARTMENT OF > VETERANS AFFAIRS, DEPARTMENT OF > 255-NETWORK CONTRACT OFFICE 15 (36C255)
FPDS Organization Code
3600-00255
Source Organization Code
100186523
Last Updated
Aug. 5, 2025
Last Updated By
jennifer.hill@va.gov
Archive Date
Sept. 11, 2025