Posted: Feb. 3, 2010, 1:24 p.m. EST
The proposed procurement is Unrestricted. NAICS Code: 236220, Size Standard is $33,500,000.00. This procurement is being advertised as a Two Phase Request for Proposal (RFP). The magnitude of construction is greater than $500,000,000. The completion period is expected to be approximately 1,100 calendar days from notice to proceed. The bonding requirements for this solicitation has been set at $750,000,000.
The project consists of the design and construction of a Tier III, 65 MW technical data center, located on Camp Williams, Utah. Basic ancillary supporting design and construction services include, but are not limited to: providing basic utility infrastructure, electrical service (primary power and temporary construction power), water, sewer, and gas. The facility itself will consist of approximately 1M SF of facility, of which 100K SF will be mission critical data center space with raised flooring and 900K SF of technical support and administrative space. Anci llary supporting facilities include, but are not limited to: water treatment facilities (pre and post), vehicle inspection facility, interim visitor control center, perimeter site security measures, fuel storage, water storage, chiller plant, fire suppression systems and 100% electrical generator and UPS back up capacity. The schedule will be very aggressive.
The project will be designed and constructed in accordance with the Uniform Federal Accessibility Standards (UFAS)/Americans with Disabilities Act (ADA) Accessibility Guidelines, and Antiterrorism Force Protection (ATFP) standards. Unified Facilities Criteria (UFC) to be an integral part of design consideration.
Posted: Jan. 25, 2010, 9:34 a.m. EST
Posted: Dec. 18, 2009, 10:20 a.m. EST

Overview

Response Deadline
Feb. 24, 2010, 10:00 a.m. EST (original: Oct. 31, 2010, 1:00 a.m. EDT) Past Due
Posted
Dec. 18, 2009, 10:20 a.m. EST (updated: Feb. 17, 2010, 1:58 p.m. EST)
Set Aside
None
Place of Performance
UTAH DATA CENTER Camp Williams, UT USA
Source

Current SBA Size Standard
$45 Million
Pricing
Likely Fixed Price
Evaluation Criteria
Best Value
Est. Level of Competition
Average
Odds of Award
53%
On 12/18/09 USACE Baltimore District issued Presolicitation W912DR-10-R-0015 for Utah Data Center due 2/24/10. The opportunity was issued full & open with NAICS 236220 and PSC Y.
Primary Contact
Name
Carlen Capenos   Profile
Phone
(410) 854-0739

Documents

Posted documents for Presolicitation W912DR-10-R-0015

Question & Answer

The AI Q&A Assistant has moved to the bottom right of the page

Opportunity Lifecycle

Procurement notices related to Presolicitation W912DR-10-R-0015

Award Notifications

Agency published notification of awards for Presolicitation W912DR-10-R-0015

Contract Awards

Prime contracts awarded through Presolicitation W912DR-10-R-0015

Incumbent or Similar Awards

Potential Bidders and Partners

Awardees that have won contracts similar to Presolicitation W912DR-10-R-0015

Similar Active Opportunities

Open contract opportunities similar to Presolicitation W912DR-10-R-0015

Additional Details

Source Agency Hierarchy
DEPT OF DEFENSE > DEPT OF THE ARMY > USACE > NAD > W2SD ENDIST BALTIMORE
FPDS Organization Code
2100-W912DR
Source Organization Code
100221492
Last Updated
Dec. 30, 2010
Last Updated By
PI33_DR_IAE_51681
Archive Date
Dec. 30, 2010