Ultra-Fast Dose Rate (FLASH) Radiation Detectors and Safety Systems for Cancer Treatment

ID: NIH/NCI 461 • Type: SBIR / STTR Topic • Match:  90%
Opportunity Assistant

Hello! Please let me know your questions about this opportunity. I will answer based on the available opportunity documents.

Please sign-in to link federal registration and award history to assistant. Sign in to upload a capability statement or catalogue for your company

Some suggestions:
Please summarize the work to be completed under this opportunity
Do the documents mention an incumbent contractor?
I'd like to anonymously submit a question to the procurement officer(s)
Loading

Description

Fast-Track proposals will be accepted. Direct-to-Phase II proposals will be accepted. Number of anticipated awards: 2-3 Budget (total costs, per award): Phase I: up to $400,000 for up to 12 months Phase II: up to $2,000,000 for up to 2 years PROPOSALS THAT EXCEED THE BUDGET OR PROJECT DURATION LISTED ABOVE MAY NOT BE FUNDED. Summary An important development in the field of radiation oncology is demonstration that ultra-fast dose rate (also known as FLASH) radiation therapy has fewer side effects than regular radiation therapy at the same delivered dose. This finding is under intense investigation globally and a race is underway to understand and subsequently implement this methodology in the clinic. The current devices that measure radiation dose lack response times sufficient to adequately address ultra-fast dose rates of 40-120 Gy/second. This is especially problematic when the total prescribed dose may be only 8-20 Gy. Current medical practice dictates that radiation dose must be given within 20% of the prescription, or else be subject to a formal reportable medical event, as regulated by the United States Nuclear Regulatory Commission. To safely utilize FLASH treatment technique in the clinic, radiation detectors need to be developed that can reliably function at dose rate from 2-10 Gy/minute to 40-120 Gy/second. Additionally, the time structure and the fluence shape of the pulse must be verified to meet FLASH specifications. FLASH radiation delivery's biological effect may be a function of a unique fine delivery structure that requires ultrafast dose measurement capacity to confirm that the proper, optimal time structure is being used (pulses versus continuous beam delivery).

Overview

Response Deadline
Nov. 14, 2023 Past Due
Posted
Aug. 25, 2023
Open
Aug. 25, 2023
Set Aside
Small Business (SBA)
Place of Performance
Not Provided
Source
Alt Source

Program
SBIR Phase I / II
Structure
Contract or Grant
Phase Detail
Phase I: Establish the technical merit, feasibility, and commercial potential of the proposed R/R&D efforts and determine the quality of performance of the small business awardee organization.
Phase II: Continue the R/R&D efforts initiated in Phase I. Funding is based on the results achieved in Phase I and the scientific and technical merit and commercial potential of the project proposed in Phase II. Typically, only Phase I awardees are eligible for a Phase II award
Duration
6 Months - 1 Year
Size Limit
500 Employees
On 8/25/23 National Institutes of Health issued SBIR / STTR Topic NIH/NCI 461 for Ultra-Fast Dose Rate (FLASH) Radiation Detectors and Safety Systems for Cancer Treatment due 11/14/23.

Documents

Posted documents for SBIR / STTR Topic NIH/NCI 461

Question & Answer

The AI Q&A Assistant has moved to the bottom right of the page

Contract Awards

Prime contracts awarded through SBIR / STTR Topic NIH/NCI 461

Incumbent or Similar Awards

Potential Bidders and Partners

Awardees that have won contracts similar to SBIR / STTR Topic NIH/NCI 461

Similar Active Opportunities

Open contract opportunities similar to SBIR / STTR Topic NIH/NCI 461

Experts for Ultra-Fast Dose Rate (FLASH) Radiation Detectors and Safety Systems for Cancer Treatment

Recommended subject matter experts available for hire