Description

Presolicitation Notice

The U.S. Army Corps of Engineers (USACE), New England District is solicitating an Invitation for Bids (IFB) for Construction Services to relocate the egress door for the Technical Information Analysis Center (TIAC) located at the Cold Regions Research and Engineering Laboratory (CRREL) in Hanover, NH. This will be a 100% Small Business Set-Aside IFB procurement. The NAICS code for the work described below is 236220 and the size standard is $45 million. The estimated cost range of this project is between $500,000 to $1 Million. Work is expected to begin this summer.

The project site is at the TIAC Building located on the CRREL campus. CRREL is a USACE research campus which solves important problems of the Department of Defense and the Nation by advancing and applying science and engineering to complex environments, materials and processes with unique core competencies related to the Earth's cold regions. This project is to construct a new egress doorway for the building and will enhance the mobility and aesthetics for a world class research facility.

The work consists of providing Construction Services to demolish the existing suspended concrete walkway (20 LF) and the associated metal egress doorway. A new secured, storefront style entrance will be constructed in a relocated area on the south facing side of the building. The new egress doorway will include a heated vestibule (100 SF) and additional work for interior construction such as new partitions and finishes to accommodate a configured egress path in the building. Ancillary renovation impacts include electrical work, HVAC, and life safety systems. All work is located on an access controlled military installation.

The TIAC building was constructed in 1992 and is primarily an office building. It is a 4-story steel structure enclosed by a mixture of 6 CMU cavity walls with brick veneer and metal stud walls with insulated metal panel. The first-floor level has a 1-foot raised access floor throughout.

This is not an invitation for bids at this time. The solicitation requirements and contract documents to include instructions for submission and the response date will be available on or about May 2025. Neither telephonic, mailed nor fax requests for hard copies will be accepted. The solicitation will only be available online; in order to view the solicitation offerors must access the System for Award Management website (www.sam.gov). To download the solicitation, offerors must access the Procurement Integrated Enterprise Environment (https://piee.eb.mil/), solicitation module. Amendments, if any, to the solicitation will be made available at the PIEE website. Registrants are responsible for the accuracy of the information on the SAM.gov Registration List. All responsible sources may submit a bid which shall be considered by the New England District. Additional questions may be emailed to the Contract Specialist at Kayla.Gonsalves@usace.army.mil. This notice does not commit the U.S. Government to contract for any supply or service.

Background
The U.S. Army Corps of Engineers (USACE), New England District is soliciting an Invitation for Bids (IFB) for Construction Services to relocate the egress door for the Technical Information Analysis Center (TIAC) located at the Cold Regions Research and Engineering Laboratory (CRREL) in Hanover, NH.

This project aims to enhance mobility and aesthetics for a world-class research facility. CRREL is a USACE research campus that addresses significant problems for the Department of Defense and the Nation by applying science and engineering to complex environments, particularly in cold regions.

Work Details
The work consists of providing Construction Services to demolish the existing suspended concrete walkway (20 LF) and the associated metal egress doorway.

A new secured, storefront style entrance will be constructed in a relocated area on the south-facing side of the building. The new egress doorway will include a heated vestibule (100 SF) and additional interior construction work such as new partitions and finishes to accommodate a configured egress path within the building. Ancillary renovation impacts include electrical work, HVAC, and life safety systems. All work is located on an access-controlled military installation.

Period of Performance
Work is expected to begin in summer 2025.

Place of Performance
Cold Regions Research and Engineering Laboratory (CRREL), Hanover, NH

Overview

Response Deadline
None
Posted
April 11, 2025, 1:15 p.m. EDT
Set Aside
Small Business (SBA)
Place of Performance
Hanover, NH United States
Source
SAM

Current SBA Size Standard
$45 Million
Pricing
Likely Fixed Price
Est. Level of Competition
Average
Est. Value Range
$500,000 - $1,000,000 (value based on agency estimated range)
Odds of Award
90%
On 4/11/25 USACE New England District issued Presolicitation W912WJ25BA018 for TIAC Egress Door Relocation, Cold Regions Research Engineering Laboratory, Hanover, NH. The opportunity was issued with a Small Business (SBA) set aside with NAICS 236220 (SBA Size Standard $45 Million) and PSC Y1JZ.
Primary Contact
Name
Kayla Gonsalves   Profile
Phone
(978) 318-8256

Documents

Posted documents for Presolicitation W912WJ25BA018

Question & Answer

Opportunity Lifecycle

Procurement notices related to Presolicitation W912WJ25BA018

Incumbent or Similar Awards

Contracts Similar to Presolicitation W912WJ25BA018

Potential Bidders and Partners

Awardees that have won contracts similar to Presolicitation W912WJ25BA018

Similar Active Opportunities

Open contract opportunities similar to Presolicitation W912WJ25BA018

Additional Details

Source Agency Hierarchy
DEPT OF DEFENSE > DEPT OF THE ARMY > USACE > NAD > W2SD ENDIST NEW ENGLAND
FPDS Organization Code
2100-W912WJ
Source Organization Code
100221388
Last Updated
April 11, 2025
Last Updated By
kayla.gonsalves@usace.army.mil
Archive Date
May 16, 2025