A Gas Chromatograph (GC) instrument is needed for air monitoring in replacement of MINICAMS instruments.

Procure two GC instruments with the following specifications:

    • Flame Photometric Detector (DFPD); one instrument with phosphorous optical filter, one instrument with sulfur optical filter
    • Chromatographic columns: one instrument DB-1 phase and one instrument DB-210 phase column; one DB-1701 column that can be installed at a later date by the user
    • Air sampling pre-concentrator trap capability with flow rate through the trap of at least 500mL/min
    • Capability to add mass flow controller and collect flow date
    • Cycle time from injection to injection of 15 minutes or less
    • Electronic pressure control (EPC) of gases
    • Displayed control zones, valve status, temperature, pressure, and voltage.
    • Built in data acquisition system
    • GC dimensions - 17 x 11 x 8.5 (width x height x depth)
    • Instrument weight approximately 25 pounds
    • Alarm capability based on analyte response

Shipping: Shall be shipped within 30 days of contract award.

Background
The U.S. Army Dugway Proving Ground, Directorate of Contracting, is contemplating the procurement of a supply contract for the purchase and delivery of Safety Air Monitoring and Analytical Referee Systems (SAMARS) Gas Chromatograph (GC). The contract is intended to replace MINICAMS instruments used for air monitoring. The solicitation is a combined synopsis/solicitation for commercial items and is issued as a Request for Quote (RFQ). The contract will be awarded on a sole source basis to Teledyne Instruments Incorporated due to the urgency, brand name, and the unavailability of other supplies or services that would satisfy agency requirements.

Work Details

A Gas Chromatograph (GC) instrument is needed for air monitoring in replacement of MINICAMS instruments.  


Procure two GC instruments with the following specifications:





    • Flame Photometric Detector (DFPD); one instrument with phosphorous optical filter, one instrument with sulfur optical filter

    • Chromatographic columns: one instrument DB-1 phase and one instrument DB-210 phase column; one DB-1701 column that can be installed at a later date by the user

    • Air sampling pre-concentrator trap capability with flow rate through the trap of at least 500mL/min

    • Capability to add mass flow controller and collect flow date

    • Cycle time from injection to injection of 15 minutes or less

    • Electronic pressure control (EPC) of gases

    • Displayed control zones, valve status, temperature, pressure, and voltage.

    • Built in data acquisition system

    • GC dimensions - 17” x 11” x 8.5” (width x height x depth)

    • Instrument weight approximately 25 pounds

    • Alarm capability based on analyte response


Period of Performance
Shall be shipped within 30 days of contract award.

Place of Performance
West Desert Test Center, BLDG 4531 B Street Mail Stop 4, Dugway Proving Ground, Utah 84022-5004.

Overview

Response Deadline
April 30, 2024, 1:00 p.m. EDT Past Due
Posted
April 25, 2024, 1:07 p.m. EDT
Set Aside
None
Place of Performance
Dugway, UT 84022 United States
Source

Current SBA Size Standard
1000 Employees
Pricing
Likely Fixed Price
Est. Level of Competition
Average
Signs of Shaping
The solicitation is open for 4 days, below average for the MICC Dugway Proving Ground.
On 4/25/24 MICC Dugway Proving Ground issued Synopsis Solicitation W911S6-23-Q-0033 for Safety Air Monitoring Replacement Gas Chromatograph (GC) due 4/30/24. The opportunity was issued full & open with NAICS 334516 and PSC 6630.
Primary Contact
Name
Nneka Okeke-Stubbs   Profile
Phone
(435) 831-2748

Secondary Contact

Name
Paul E. Frailey   Profile
Phone
(435) 831-2587

Documents

Posted documents for Synopsis Solicitation W911S6-23-Q-0033

Question & Answer

The AI Q&A Assistant has moved to the bottom right of the page

Opportunity Lifecycle

Procurement notices related to Synopsis Solicitation W911S6-23-Q-0033

Award Notifications

Agency published notification of awards for Synopsis Solicitation W911S6-23-Q-0033

Contract Awards

Prime contracts awarded through Synopsis Solicitation W911S6-23-Q-0033

Incumbent or Similar Awards

Contracts Similar to Synopsis Solicitation W911S6-23-Q-0033

Potential Bidders and Partners

Awardees that have won contracts similar to Synopsis Solicitation W911S6-23-Q-0033

Similar Active Opportunities

Open contract opportunities similar to Synopsis Solicitation W911S6-23-Q-0033

Experts for Safety Air Monitoring Replacement Gas Chromatograph (GC)

Recommended subject matter experts available for hire

Additional Details

Source Agency Hierarchy
DEPT OF DEFENSE > DEPT OF THE ARMY > AMC > ACC > MISSION & INSTALLATION CONTRACTING COMMAND > 418TH CSB
FPDS Organization Code
2100-W911S6
Source Organization Code
500036820
Last Updated
May 15, 2024
Last Updated By
nneka.okeke-stubbs.civ@army.mil
Archive Date
May 15, 2024