Search Contract Opportunities

Replace Roof Building 797

ID: N4008523R2878 • Type: Solicitation

Description

M&R MACC:

Only M&R MACC Contractors listed on the General Requirements cover page may submit a proposal for this ROICC Camp Lejeune area of responsibility project. See attached documents for scope of work and any applicable drawings.

Background
The solicitation is for the replacement of the shingle and flat roof of Building 797 at Camp Lejeune, North Carolina. The intention is to obtain supervision, expertise, labor, materials, and equipment for the project.

Work Details
The detailed requirements include removing existing membrane roof and insulation, replacing the flat roof section with a modified bitumen roofing system, removing and replacing roof drain strainer assemblies, removing and replacing skylights and wind-driven turbine exhaust ventilators, installing new roof curb caps, removing existing asphalt shingle roof from Building 797 and attached walkway, installing an architectural single roofing system, reattaching all lighting protection, and installing a roof information placard inside the telecom room 016. The contractor is required to make a site visit, perform work in a professional manner adjacent to a medical facility, coordinate work schedule with the contracting officer's representative, have all materials on-site prior to commencement of work, install all materials according to manufacturer’s instructions, and coordinate all work and schedules with the contracting officer's designated representative and the building occupants.

Period of Performance
The contract completion date is 180 days after award.

Place of Performance
The project will be performed at Building 797, Camp Lejeune in North Carolina.

Overview

Response Deadline
Aug. 24, 2023, 3:00 p.m. EDT Past Due
Posted
Aug. 10, 2023, 3:54 p.m. EDT (updated: Aug. 24, 2023, 2:45 p.m. EDT)
Set Aside
Small Business (SBA)
Place of Performance
Camp Lejeune, NC 28547 United States
Source
SAM

Current SBA Size Standard
$45 Million
Pricing
Likely Fixed Price
Est. Level of Competition
Average
Signs of Shaping
67% of obligations for similar contracts within the Department of the Navy were awarded full & open.
On 8/10/23 Naval Facilities Engineering Command issued Solicitation N4008523R2878 for Replace Roof Building 797 due 8/24/23. The opportunity was issued with a Small Business (SBA) set aside with NAICS 236220 (SBA Size Standard $45 Million) and PSC Z2JZ.
Primary Contact
Name
Clifton Gaither   Profile
Phone
(910) 451-5598
Fax
(910) 451-5629

Secondary Contact

Name
Lauren Loconto   Profile
Phone
(910) 451-2582
Fax
None

Documents

Posted documents for Solicitation N4008523R2878

Question & Answer

Incumbent or Similar Awards

Contracts Similar to Solicitation N4008523R2878

Potential Bidders and Partners

Awardees that have won contracts similar to Solicitation N4008523R2878

Similar Active Opportunities

Open contract opportunities similar to Solicitation N4008523R2878

Additional Details

Source Agency Hierarchy
DEPT OF DEFENSE > DEPT OF THE NAVY > NAVFAC > NAVFAC ATLANTIC CMD > NAVFAC MID-ATLANTIC > NAVAL FAC ENGINEERING CMD MID LANT
FPDS Organization Code
1700-N40085
Source Organization Code
100513874
Last Updated
Sept. 8, 2023
Last Updated By
clifton.gaither@navy.mil
Archive Date
Sept. 8, 2023