B1104

  1. Provide double steel pipe scaffolding for temporary works.
  2. Repair/patch/clean the existing deteriorated/damaged fasteners, protected metal (PTML) roof panel before applying new water proofing coating system.
  3. Remove all scale, dirt, any other contaminants and apply metal primer recommended by manufacturer to all entire PTML roof to prepare existing surface for applying acrylic fluid-applied water proofing coating system.
  4. Apply one coat of base coat to the substrate especially on the vertical seams, horizontal laps, roof penetrations, joints, and exposed mechanical fasteners.
  5. Lay out fabrics into the wet base coat and apply a second coat of base coat immediately applied over the top to saturate the fabrics fully (The base coat shall only be applied by manufacture's recommended/approved tools such as brushes - unapproved rolling and/or spraying are strictly prohibited).
  6. Apply 2 coats of finish coat entirely according to the manufacture's standard procedure of the acrylic fluid-applied water proofing coating system.
  7. Replace existing rain gutters and downspouts with new ones including all accessories and concrete splash blocks.
  8. Remove all construction debris originated from the project and clean up the job site.
  9. The contractor shall be responsible to repair all damages to existing areas caused by the project and to match condition to adjacent areas.

B1142

  1. Provide high place operation vehicle for temporary works.
  2. Replace existing rain gutters and downspouts with new ones including all accessories and concrete splash blocks.
  3. Remove all construction debris originated from the project and clean up the job site.
  4. The contractor shall be responsible to repair all damages to existing areas caused by the project and to match condition to adjacent areas.

B1162

  1. Provide double steel pipe scaffolding for temporary works.
  2. Repair/patch/clean the existing deteriorated/damaged fasteners, protected metal (PTML) roof panel before applying new water proofing coating system.
  3. Remove all scale, dirt, any other contaminants and apply metal primer recommended by manufacturer to all entire PTML roof to prepare existing surface for applying acrylic fluid-applied water proofing coating system.
  4. Apply one coat of base coat to the substrate especially on the vertical seams, horizontal laps, roof penetrations, joints, and exposed mechanical fasteners.
  5. Lay out fabrics into the wet base coat and apply a second coat of base coat immediately applied over the top to saturate the fabrics fully (The base coat shall only be applied by manufacture's recommended/approved tools such as brushes - unapproved rolling and/or spraying are strictly prohibited).
  6. Apply 2 coats of finish coat entirely according to the manufacture's standard procedure of the acrylic fluid-applied water proofing coating system.
  7. Replace existing rain gutters and downspouts with new ones including all accessories and concrete splash blocks.
  8. Remove all construction debris originated from the project and clean up the job site.
  9. The contractor shall be responsible to repair all damages to existing areas caused by the project and to match condition to adjacent areas.

Overview

Award ID
W91QVN-19-D-0006
Reported Award
$206,467
Award Date
June 29, 2023
Posted
Aug. 24, 2023, 9:43 p.m. EDT
Set Aside
None
NAICS
None
PSC
None
Place of Performance
Not Provided
Source
Repair Leaky Roof for Aircraft Maintenance Facility Bldg#1104, #1142, #1162, Osan AB (W90VN6-23-F-0045) was awarded to Krima Construction on 8/24/23 by 629th Contracting Team.
Primary Contact
Name
Chaeyong Yi   Profile
Phone
7576018

Documents

Posted documents for Award Notice W90VN6-23-F-0045

Question & Answer

The AI Q&A Assistant has moved to the bottom right of the page

Award Notifications

Agency published notification of awards for Award Notice W90VN6-23-F-0045

Similar Active Opportunities

Open contract opportunities similar to Award Notice W90VN6-23-F-0045

Additional Details

Source Agency Hierarchy
DEPT OF DEFENSE > DEPT OF THE ARMY > AMC > ACC > ACC-OO > 411TH CSB
FPDS Organization Code
2100-W90VN6
Source Organization Code
500045558
Last Updated
Sept. 1, 2023
Last Updated By
chaeyong.yi5.ln@mail.mil
Archive Date
Sept. 1, 2023