Search Contract Opportunities

Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point

ID: W9127N26QA082 • Type: Sources Sought • Match:  100%
Opportunity Assistant

Hello! Please let me know your questions about this opportunity. I will answer based on the available opportunity documents.

Please sign-in to link federal registration and award history to assistant. Sign in to upload a capability statement or catalogue for your company

Popular Questions:
Generate a draft:
Loading

Description

Sources Sought Number: W9127N26QA082

Subject: Sources Sought for Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point.

PSC: 6150 Maintenance, Repair, and Rebuilding of Equipment: Transformers.

NAICS: 335311 - Power, Distribution, and Specialty Transformer Manufacturing

General. This Sources Sought is issued for informational and market research purposes only. It is not a Request for Proposal (RFP), Request for Quotation (RFQ), Invitation for Bid (IFB), or a solicitation under FAR Subpart 5.2.

The purpose of this Sources Sought is to obtain information regarding industry interest, capabilities, and qualifications so the Government can make informed acquisition decisions. We encourage responses from both large and small businesses, including Small Business, Small Disadvantaged Business, 8(a) firms, HUBZone firms, Woman-Owned Small Business (WOSB), Economically Disadvantaged Woman-Owned Small Business (EDWOSB), Service-Disabled Veteran-Owned Small Business (SDVOSB), and Veteran-Owned Small Business (VOSB). All interested parties are strongly encouraged to respond.

Responses to this Sources Sought will be used by the Government to support market research, assess available sources, and inform any future solicitation.

Please provide a capability statement demonstrating your ability to fulfill ALL the requirements identified in the Statement of Work (SOW). If you are unable to provide all the requirements, please clearly identify it in your capability statement.

This will help us accurately assess your qualifications for the full requirement.

Formal Sources Sought Response Due: 22 May 2026 at 12:00 PM PDT.

The Contractor shall provide all personnel, equipment, tools, materials, supervision, and other items and services necessary to replace vacuum interrupters on circuit breaker as defined in this Statement of Work (SOW). The circuit breaker is an Eaton / Cutler Hammer brand, 150VCP-W50C circuit breaker with serial number 03084859.

Scope:

This SOW covers replacement of vacuum interrupters, calibration and testing of one (1) Eaton / Cutler Hammer type VCP-W50C vacuum circuit breaker. Satisfactory completion of this work requires that

refurbishment is conducted either in accordance with the original manufacturer's instructions for replacement, installation, maintenance (I.B. 32-255-1G Eaton "Instructions for Installation, Operation and Maintenance of Type VCP-W Vacuum Circuit Breakers"). In strict accordance with the original manufacturer's drawings and other documentation or following ANSI/PEARL electrical equipment reconditioning standards. Acceptable performance of the circuit breaker is also to be verified with testing performed in accordance with NETA Maintenance Testing Specifications (MTS)

  1. Please read the SOW and photos in its entirety to ensure a complete understanding of the requirement before responding to this Sources Sought.
Background
This Sources Sought is issued by the U.S. Army Corps of Engineers for informational and market research purposes regarding the refurbishment of an Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker. The goal is to assess industry interest, capabilities, and qualifications to inform future acquisition decisions.

The circuit breaker serves as a feeder breaker for station service transformers at the Lookout Point Dam in Lowell, OR, and has sustained contact erosion from normal operation, necessitating refurbishment.

Work Details
The Contractor shall provide all personnel, equipment, tools, materials, supervision, and other items necessary to replace vacuum interrupters on the Eaton/Cutler Hammer 150VCP-W50C circuit breaker (serial number 03084859). The work includes:
- Replacement of all three vacuum pole assemblies with new assemblies that meet IEEE/ANSI C37.04 and C37.06 standards.
- Factory calibration of the circuit breaker following the replacement.
- Testing of the circuit breaker upon completion to ensure it meets manufacturer specifications, including insulation resistance, contact resistance, timing, and over-potential tests. A report with test results must be submitted.
- All parts and repairs must be compatible with the Eaton type VCP-W50C circuit breaker and rated to meet or exceed performance ratings specified on the breaker nameplate:
- Maximum Voltage: 17,500V
- Continuous Current: 1200 A
- Lightning Impulse Withstand Voltage: 95 kV peak
- Interrupting Time: 50 ms
- Short-Circuit Current: 50kA rms
- A 12-month warranty will be provided for the refurbished circuit breaker.

Place of Performance
Lookout Point Dam, Lowell, OR.

Overview

Response Deadline
May 26, 2026, 3:00 a.m. EDT Due in 9 Days
Posted
May 12, 2026, 1:19 p.m. EDT
Set Aside
None
Place of Performance
Lowell, OR 97452 United States
Source

Current SBA Size Standard
800 Employees
Pricing
Likely Fixed Price
Est. Level of Competition
Average
Est. Value Range
Experimental
$25,000 - $75,000 (AI estimate)
Odds of Award
54%
On 5/12/26 USACE Portland District issued Sources Sought W9127N26QA082 for Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point due 5/26/26. The opportunity was issued full & open with NAICS 335311 and PSC 6150.
Primary Contact
Name
Consuelo Kiser   Profile
Phone
(785) 806-7187

Documents

Posted documents for Sources Sought W9127N26QA082

Opportunity Assistant


AI Analysis

AI Generate

Incumbent or Similar Awards

Contracts Similar to Sources Sought W9127N26QA082

Potential Bidders and Partners

Awardees that have won contracts similar to Sources Sought W9127N26QA082

Similar Active Opportunities

Open contract opportunities similar to Sources Sought W9127N26QA082

Experts for Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point

Recommended subject matter experts available for hire

Additional Details

Source Agency Hierarchy
DEPT OF DEFENSE > DEPT OF THE ARMY > USACE > NWD > US ARMY ENGINEER DISTRICT PORTLAND
FPDS Organization Code
2100-W9127N
Source Organization Code
100255230
Last Updated
May 12, 2026
Last Updated By
consuelo.j.kiser@usace.army.mil
Archive Date
June 10, 2026