Description

THIS IS A SOURCES SOUGHT NOTICE ANNOUNCEMENT FOR MARKET RESEARCH PURPOSES ONLY The VHA Government intends to set-aside this requirement for SDVOSB. However, the Government is interested in other potential sources that can provide the required product and/or services. Interested parties are encouraged to respond to this source sought notice announcement. The purpose of this SOURCES SOUGHT ANNOUNCEMENT is to gain knowledge of potential qualified sources and their size classification (HUBZone, 8(a), small, small disadvantage, service-disabled veteran owned small business, veteran owned small business, or large business) relative to NAICS 811310. The Government is conducting market research to determine potential sources having the skills, capabilities, and experience to perform the described work. Responses to this SOURCES SOUGHT ANNOUCEMENT will be used by the Government to make appropriate acquisition decisions. After review of the responses to this SOURCES SOUGHT NOTICE, a solicitation announcement may be published on Contract Opportunities (Sam.gov) or other Electronic Governmentwide Point of Entry (EGPE). Responses to this SOURCES SOUGHT NOTICE are not considered adequate responses to any potential solicitation announcement. This is a SOURCES SOUGHT NOTICE ANNOUCEMENT ONLY and is NOT a request for proposals or quotes. Information received as a result of this sources sought notice will be used solely for the purpose of determining whether to conduct a competitive procurement. This notice does not represent a commitment by the Government to pay for costs incurred in the preparation and submission of information or any other costs incurred as a response to this SOURCE SOUGHT NOTICE ANNOUNCEMENT. Respondents will NOT be notified of the results or the Government s determination on whether to conduct a competitive procurement and/or set-aside to limit competition among any specific socio-economic category. All interested contractors should notify the Network Contracting Office 15 via email at Gregory.McMillan@va.gov by (Time) a.m. Central Standard Time on (Date). Responses must include the sources sought notice announcement number and title in the subject line of their email response AND the below or attached Contractor Fillable Form. In response to this SOURCES SOUGHT NOTICE ANNOUNCEMENT, please provide the information below: SOURCES SOUGHT CONTRACTOR INFORMATION FORM for VHA | RPOC | NETWORK CONTRACTING OFFICE 15 Use this form to provide contractor s general information. Please limit response to one page. The box at the bottom of this form may be used to clarify any requested information. Contractor Information: Business Name: Address: Name of POC for Business: Phone Number of POC: Email of POC: Type of Business: (check all that apply) SBA certified 8(a) firm SBA certified HUBZone Small Business Service-Disabled Veteran-Owned Small Business Veteran-Owned Small Business Economically Disadvantaged Women-Owned Small Business Women-Owned Small Business Other: ___________________________ Large Business Please identify number of projects your organization has performed at the different ranges identified below: <$500K ______ $500K ~ $1M ______ $1M ~ $2M ______ $2M ~ $5M ______ >$5m ______ CAPABILITIES STATEMENT: Market Pricing for scope of work IAW SOW: The John J Pershing VA Medical Center requires a preventive maintenance contract for the following chillers to enhance operational efficiency and reduce the risk of system downtime. This service encompasses preventive maintenance for water-cooled chillers, including two Trane Chillers (Model RTHDUCZFXE0UAFZA3LALF3A2LALAVXQXEXAAXXYZ73AJUAX4XXXXVX) located in Mechanical Room G0061 on the Ground Floor of Building 1, and two Carrier Chillers (Model 30HXA161RZE661KA) situated in the 6th-floor Penthouse Mechanical Room of Building 1. The scope includes annual leak detection using an electronic leak detector, inspection of motor and compressor bearings, greasing, replacement of the oil filter with a manufacturer-approved filter, sampling and laboratory analysis of oil, and reporting to the VA. Additional tasks involve verifying oil and refrigerant levels, checking safety devices and panel diagnostics, inspecting control panels for proper operation, changing coolant in variable speed drives, inspecting drives, and performing operational checks after maintenance. Eddy current testing will be conducted on both chillers during the base year and three subsequent years, focusing on evaporator and condenser components in the initial year. Additionally, the scope includes preventive maintenance for the MRI air-cooled chiller, Dimplex Thermal Solutions Model WO2-2-5000-2P-NF-L-M-407C, located south of the MRI Building adjacent to Building 1. Services will include routine inspections such as refrigerant leak detection, condenser coil and fan operation, electrical verification (voltage, amperage, wiring integrity), inspection of contactors and relays, verification of thermistors and transducers, safety device checks, oil sampling with laboratory analysis, refrigerant and oil levels, and inspection of the chilled water system components, including flow switches and pumps. Pump inspections will include rotation, coupling condition, noise assessment, and operational testing of the entire system. Systems covered include: - John J Pershing VA Medical Center Trane Chiller Model RTHDUCZFXE0UAFZA3LALF3A2LALAVXQXEXAAXXYZ73AJUAX4XXXXVX (Main Chiller #1) - John J Pershing VA Medical Center Trane Chiller Model RTHDUCZFXE0UAFZA3LALF3A2LALAVXQXEXAAXXYZ73AJUAX4XXXXVX (Main Chiller #2) - John J Pershing VA Medical Center Carrier Chiller Model 30HXA161RZE661KA (Backup Chiller #1) - John J Pershing VA Medical Center Carrier Chiller Model 30HXA161RZE661KA (Backup Chiller #2) - John J Pershing VA Medical Center Dimplex Thermal Solutions Chiller Model WO2-2-5000-2P-NF-L-M-407C (MRI Chiller)
Background
The Veterans Health Administration (VHA) Government is conducting market research to identify potential qualified sources for a preventive maintenance contract for chillers at the John J. Pershing VA Medical Center in Poplar Bluff, Missouri. The agency aims to enhance operational efficiency and reduce system downtime through this contract. The Government intends to set aside this requirement for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) but is also interested in responses from other potential sources, including various socio-economic classifications.

Work Details
The contractor will provide preventive maintenance services for the following chillers: two Trane Chillers (Model RTHDUCZFXE0UAFZA3LALF3A2LALAVXQXEXAAXXYZ73AJUAX4XXXXVX) located in Mechanical Room G0061 and two Carrier Chillers (Model 30HXA161RZE661KA) situated in the 6th-floor Penthouse Mechanical Room of Building 1. The tasks include:
- Annual leak detection using an electronic leak detector.
- Inspection of motor and compressor bearings, greasing, and replacement of the oil filter with a manufacturer-approved filter.
- Sampling and laboratory analysis of oil, with reporting to the VA.
- Verification of oil and refrigerant levels, checking safety devices and panel diagnostics, inspecting control panels for proper operation.
- Changing coolant in variable speed drives, inspecting drives, and performing operational checks after maintenance.
- Eddy current testing on both chillers during the base year and three subsequent years, focusing on evaporator and condenser components in the initial year.

Additionally, preventive maintenance for an MRI air-cooled chiller (Dimplex Thermal Solutions Model WO2-2-5000-2P-NF-L-M-407C) will include routine inspections such as refrigerant leak detection, condenser coil operation checks, electrical verification (voltage, amperage), inspection of contactors and relays, verification of thermistors and transducers, safety device checks, oil sampling with laboratory analysis, refrigerant and oil levels checks, and inspection of chilled water system components including flow switches and pumps.

Place of Performance
The contract will be performed at the John J. Pershing VA Medical Center located at 1500 N Westwood Blvd, Poplar Bluff, Missouri 63901.

Overview

Response Deadline
Aug. 15, 2025, 9:00 a.m. EDT Past Due
Posted
Aug. 7, 2025, 3:15 p.m. EDT
Set Aside
None
Place of Performance
Department of Veterans Affairs Poplar Bluff, MO 63901 United States
Source

Current SBA Size Standard
$12.5 Million
Pricing
Likely Fixed Price
Est. Level of Competition
Low
Odds of Award
45%
Signs of Shaping
The solicitation is open for 7 days, below average for the VISN 15: Heartland Network.
On 8/7/25 VISN 15: Heartland Network issued Sources Sought 36C25525Q0535SSN for CHILLER MAINTENANCE SERVICES John J Pershing VAMC Poplar Bluff, Missouri due 8/15/25. The opportunity was issued full & open with NAICS 811310 and PSC J041.
Primary Contact
Title
Contract Specialist
Name
Greg McMillan Sr.   Profile
Phone
(913) 758-9919

Documents

Posted documents for Sources Sought 36C25525Q0535SSN

Opportunity Assistant


AI Analysis

AI Generate

Incumbent or Similar Awards

Contracts Similar to Sources Sought 36C25525Q0535SSN

Potential Bidders and Partners

Awardees that have won contracts similar to Sources Sought 36C25525Q0535SSN

Similar Active Opportunities

Open contract opportunities similar to Sources Sought 36C25525Q0535SSN

Experts for CHILLER MAINTENANCE SERVICES John J Pershing VAMC Poplar Bluff, Missouri

Recommended subject matter experts available for hire

Additional Details

Source Agency Hierarchy
VETERANS AFFAIRS, DEPARTMENT OF > VETERANS AFFAIRS, DEPARTMENT OF > 255-NETWORK CONTRACT OFFICE 15 (36C255)
FPDS Organization Code
3600-00255
Source Organization Code
100186523
Last Updated
Sept. 14, 2025
Last Updated By
gregory.mcmillan@va.gov
Archive Date
Sept. 14, 2025