RFQ Emergency Generator Repairs Baltimore VAMC Loch Raven VAMC One Year Purchase Order

ID: 36C24526Q0658 • Type: Synopsis Solicitation • Match:  90%
Opportunity Assistant

Hello! Please let me know your questions about this opportunity. I will answer based on the available opportunity documents.

Please sign-in to link federal registration and award history to assistant. Sign in to upload a capability statement or catalogue for your company

Popular Questions:
Generate a draft:
Loading

Description

1. PURPOSE 1.1 The purpose of this PWS is to perform corrective maintenance and repairs on eight (8) diesel emergency generators and fuel polishing at the Baltimore VA Medical Center and Loch Raven Medical Center to restore each unit to OEM-compliant, leak free operation and to verify performance under load testing consistent with healthcare facility requirements for emergency and standby power. The work supports critical healthcare operations; emergency power systems must meet NFPA 110 performance classifications and operational testing requirements for healthcare facilities, and interface with NFPA 99 life safety expectations.
Background
The Department of Veterans Affairs is issuing this solicitation for the purpose of performing corrective maintenance and repairs on eight diesel emergency generators at the Baltimore VA Medical Center and Loch Raven Medical Center. The goal is to restore each unit to OEM-compliant, leak-free operation and verify performance under load testing, which is critical for healthcare operations that rely on emergency power systems meeting NFPA 110 performance classifications and operational testing requirements.

Work Details
The contractor will perform the following tasks:
1. Diagnose and repair/replace all identified leaks (coolant, oil, fuel, exhaust) and system defects; reseal gaskets/O-rings; replace degraded hoses, valves, manifolds/bellows, turbo oil feed/drain lines, thermostat housings, and other components as indicated. All hoses, gaskets, and O-rings shall be replaced.

2. Perform Cooling System Service: flush with cleaner, distilled rinse, refill with appropriate coolant; service radiators where indicated.

3. Conduct Preventive Maintenance (PM): engine oil, filters, fuel/water separators, air filter, belts/tensioners, battery/cables as identified.

4. Execute post-repair operational and load bank testing to demonstrate compliance with NFPA 110 expectations for healthcare emergency power readiness.

5. Specific generator tasks include replacing alternator belts, rocker box gaskets, turbo drain lines, resealing oil filter housing and all leaking plugs using pipe sealant, replacing exhaust bellows and related hardware among others. Major repairs such as rear main seal replacement are excluded due to extensive labor requirements.

Period of Performance
The contract period is estimated from August 17, 2026 to August 16, 2027.

Place of Performance
The work will be performed at the Baltimore VA Medical Center located at 10 N Greene St., Baltimore MD 21201 and Loch Raven Medical Center.

Bidder Requirements
Bidders must demonstrate competency and relevant experience with emergency generator systems as a Primary Vendor. They must provide evidence of capability/expertise including licensing and experience in maintaining and repairing emergency generators for at least five years. Additionally, bidders must submit a detailed subcontracting plan if applicable.
Loading Map
Loading Map

Overview

Response Deadline
Aug. 17, 2026, 10:00 a.m. EDT Due in 33 Days
Posted
July 14, 2026, 8:26 a.m. EDT
Set Aside
None
Place of Performance
Department of Veterans Affairs Loch Raven -Baltimore VAMCs Baltimore, MD 21201 USA
Source
Links

Current SBA Size Standard
$12.5 Million
Pricing
Likely Fixed Price
Est. Level of Competition
Low
Est. Value Range
Experimental
$180,000 - $450,000 (AI estimate)
On 7/14/26 VISN 5: Capitol Health Care Network issued Synopsis Solicitation 36C24526Q0658 for RFQ Emergency Generator Repairs Baltimore VAMC Loch Raven VAMC One Year Purchase Order due 8/17/26. The opportunity was issued full & open with NAICS 811310 and PSC J030.
Primary Contact
Title
Contracting Officer
Name
William Chris Galletta   Profile
Phone
(410) 637-1506

Documents

Posted documents for Synopsis Solicitation 36C24526Q0658

Opportunity Assistant


AI Analysis

AI Generate

Incumbent or Similar Awards

Contracts Similar to Synopsis Solicitation 36C24526Q0658

Potential Bidders and Partners

Awardees that have won contracts similar to Synopsis Solicitation 36C24526Q0658

Similar Active Opportunities

Open contract opportunities similar to Synopsis Solicitation 36C24526Q0658

Experts for RFQ Emergency Generator Repairs Baltimore VAMC Loch Raven VAMC One Year Purchase Order

Recommended subject matter experts available for hire

Additional Details

Source Agency Hierarchy
VETERANS AFFAIRS, DEPARTMENT OF > VETERANS AFFAIRS, DEPARTMENT OF > 245-NETWORK CONTRACT OFFICE 5 (36C245)
FPDS Organization Code
3600-00245
Source Organization Code
100173468
Last Updated
July 14, 2026
Last Updated By
William.Galletta@va.gov
Archive Date
Oct. 16, 2026