Search Contract Opportunities

HVAC Controls – Schneider Electric

ID: 36C26024Q0865 • Type: Sources Sought • Match:  95%
Opportunity Assistant

Hello! Please let me know your questions about this opportunity. I will answer based on the available opportunity documents.

Please sign-in to link federal registration and award history to assistant. Sign in to upload a capability statement or catalogue for your company

Some suggestions:
Please summarize the work to be completed under this opportunity
Draft a sources sought response template for this opportunity
Do the documents mention an incumbent contractor?
I'd like to anonymously submit a question to the procurement officer(s)
Loading

Description

This is a request for information (RFI) for market research purposes only to determine the availability of potential businesses with capabilities to provide the products described below. It is neither a solicitation announcement nor a request for proposals or quotes and does not obligate the Government to award a contract. Responses to this RFI notice must be in writing.

Prodcut Details:

HVAC Controls Schneider Electric -

QTY-1, EA, Actuator part

QTY-1, EA, Three way control valve.

Background
The Veterans Health Administration (VHA) is seeking information for market research purposes to identify potential businesses capable of providing HVAC controls. This request is not a solicitation for proposals or quotes and does not obligate the Government to award a contract. The goal is to gather information on the availability of HVAC control products from manufacturers or authorized distributors.

Work Details
The contract involves the provision of HVAC Controls specifically from Schneider Electric, including:
- **Actuator** (Part Number: M313A01)
- Actuator Type: Electric
- Control Signal: Proportional
- Control Signal Range: 0 to 10 VDC, 0 to 5 VDC, 4 to 20 mAdc, 5 to 10 VDC
- Loss of Power Type: Spring Return
- Power Input Voltage: 24 VAC
- Mechanical Movement: Rotary
- Protection Rating: NEMA 2

- **Three Way Control Valve** (Part Number: VBBN3A01)
- Voltage: 24 Vac for floating and proportional control; multi-voltage options available.
- Control Signal: Two-Position, Floating, or Proportional.
- Materials: Thermoplastic base and cover approved for use in air plenums.

Specifications include operational temperature limits, humidity tolerance, and various performance metrics such as seat leakage and pressure limits.

Place of Performance
Department of Veterans Affairs, Puget Sound VAMC, Seattle WA, USA

Overview

Response Deadline
Aug. 30, 2024, 6:00 p.m. EDT Past Due
Posted
Aug. 26, 2024, 6:46 p.m. EDT
Set Aside
None
Place of Performance
Spokane, WA 99205 United States
Source

Current SBA Size Standard
1250 Employees
Pricing
Likely Fixed Price
Est. Level of Competition
Low
Est. Value Range
Experimental
$5,000 - $15,000 (AI estimate)
Odds of Award
20%
Signs of Shaping
The solicitation is open for 3 days, below average for the VISN 20: Northwest Network.
On 8/26/24 VISN 20: Northwest Network issued Sources Sought 36C26024Q0865 for HVAC Controls – Schneider Electric due 8/30/24. The opportunity was issued full & open with NAICS 333415 and PSC 4130.
Primary Contact
Name
Derek Crockett   Profile
Phone
None

Documents

Posted documents for Sources Sought 36C26024Q0865

Question & Answer

The AI Q&A Assistant has moved to the bottom right of the page

Incumbent or Similar Awards

Potential Bidders and Partners

Awardees that have won contracts similar to Sources Sought 36C26024Q0865

Similar Active Opportunities

Open contract opportunities similar to Sources Sought 36C26024Q0865

Additional Details

Source Agency Hierarchy
VETERANS AFFAIRS, DEPARTMENT OF > VETERANS AFFAIRS, DEPARTMENT OF > 260-NETWORK CONTRACT OFFICE 20 (36C260)
FPDS Organization Code
3600-00260
Source Organization Code
100186526
Last Updated
Sept. 14, 2024
Last Updated By
derek.crockett@va.gov
Archive Date
Sept. 14, 2024