Good day, SDVOSB's, VOSB's & SB's Sources Sought Pre-Solicitation

This Sources Sought is issued solely for informational and planning purposes only. It does not constitute the issuance of a solicitation or a promise to issue solicitation in the future. The purpose of this notice is to conduct market research and obtain information from qualified SB and large businesses. This is not a request for bids, quotes, offers, or proposals. The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible. If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB's, the requirement may be solicited as a VOSB or a SB set aside, if no or not enough small business responses are received, this may be solicited as unrestricted, all interested parties responding shall be eligible to compete.

Please direct reply in the affirmative via email if you are interested and can provide the required product/service for this requirement. Please provide your capability statement, and any other supportive documentation. I will accept responses to this Sources Sought until the 13th of July 2026 14:00, thanks.

General: C.W. Bill Young Veterans Affairs Medical Center10,000 Bay Pines Blvd, Bay Pines, Florida 33744, has a requirement for four (4) geriatric simulation mannequins and 3 decontamination capable mannequins for Bay Pines VA Medical Center.

Background: The BPVAHCS has requires 4 simulation mannequins to be used for staff training on the evacuation buses. Additionally, the BPVAHCS has a decontamination program that needs the decontamination mannequins for training and exercises.

Scope of Work: The mannequins provided must be equal to the salient characteristics listed below. Explanation of how equal meets each salient characteristic must be included with quote.

3.1 Salient Characteristics (Geriatric Simulation Mannequin x 4)

  1. The mannequin should be a full body with the approximate height of an adult (approx. 5 ft) and weigh at least 60lbs. but no more than 80lbs.
  2. It should be made of material that will accurately simulate a human body and tissue, while still allowing for the required features listed below.
  3. The material shall be made of non-toxic material and safe to handle and touch
  4. Adult, elderly mannequin
  5. Interchangeable pupils to allow for normal, constricted or dilation
  6. Limbs must have a range of motion comparable to an average person
  7. Mannequin must be able to be turned, transferred, or position for patient care
  8. Must allow for oral and nasal intubation
  9. Must allow for ventilation
  10. Must allow for CPR compression
  11. Must allow airway management
  12. Must allow for urinary catheterization
  13. Must allow for wound care
  14. Must allow for tracheostomy care
  15. Must all for NG/PEG tube
  16. Must allow for ostomy care
  17. Must allow for IVs and injection sites
  18. Must allow for medication administration
  19. Must feature heart, lung, and bowel sounds
  20. Must allow for ECG placement
  21. Must allow for monitoring of blood pressure, temperature, SpO2, and ECG.
  22. Must allow for manual carotid pulse

3.2 Salient Characteristics (WMD/CBRNE/Decon Mannequin x 3)

  1. The mannequin should be a full body with the approximate height of an adult (approx. 5 ft) and weigh at least 60lbs. but no more than 80lbs.
  2. It should be made of material that will accurately simulate a human body for the purposes of decontamination.
  3. It should be made of material that can sustain being saturated in water and cleaning solutions for the purposes of decontamination
  4. It should be made of material that can be easily cleaned and dried after being processed through decontamination.
  5. It should be durable and be non-electronic construction, able to withstand wet and outdoor environments
  6. The material shall be made of non-toxic material and safe to handle and touch
  7. Full body mannequin designed for decontamination training and practice
  8. Intubation head allowing for airway management
  9. IV arm with injection site
  10. Designed to withstand decontamination practice and use in hazmat exercises
  11. Must allow for moulage
Background
The C.W. Bill Young Veterans Affairs Medical Center, located at 10,000 Bay Pines Blvd, Bay Pines, Florida 33744, has a requirement for geriatric simulation mannequins and decontamination capable mannequins. The purpose of this procurement is to enhance staff training on evacuation procedures and support the decontamination program through realistic training scenarios.

Work Details
The contract requires the delivery of four (4) geriatric simulation mannequins and three (3) decontamination capable mannequins. The salient characteristics for the geriatric simulation mannequins include:
1. Full body mannequin approximately 5 ft tall weighing between 60-80 lbs.
2. Made from material that simulates human body and tissue.
3. Non-toxic material safe for handling.
4. Features interchangeable pupils for various states (normal, constricted, dilated).
5. Limbs with a range of motion similar to an average person.
6. Capable of being positioned for patient care and allows for various medical procedures including intubation, ventilation, CPR, urinary catheterization, wound care, tracheostomy care, NG/PEG tube management, ostomy care, IVs and injections, medication administration, and monitoring vital signs.

The salient characteristics for the decontamination capable mannequins include:
1. Full body mannequin approximately 5 ft tall weighing between 60-80 lbs.
2. Made from material suitable for decontamination processes.
3. Durable construction that withstands saturation in water and cleaning solutions.
4. Non-electronic design suitable for wet environments.
5. Allows for intubation head use and IV arm with injection site.

Place of Performance
C.W. Bill Young Veterans Affairs Medical Center, Bay Pines, Florida 33744 UNITED STATES

Bidder Requirements
Bidders must provide a capability statement demonstrating their ability to meet the specified requirements and salient characteristics outlined in the solicitation.

Overview

Response Deadline
July 13, 2026, 2:00 p.m. EDT Due in 12 Days
Posted
July 1, 2026, 10:12 a.m. EDT
Set Aside
None
Place of Performance
Bay Pines, FL 33744 United States
Source

Current SBA Size Standard
800 Employees
Pricing
Likely Fixed Price
Est. Level of Competition
Low
Est. Value Range
Experimental
$70,000 - $140,000 (AI estimate)
Odds of Award
30%
On 7/1/26 VISN 8: Sunshine Healthcare Network issued Sources Sought 36C24826Q0892 for Geriatric & Decon Manikins due 7/13/26. The opportunity was issued full & open with NAICS 339113 and PSC 6515.
Primary Contact
Name
Michael A Shook   Profile
Phone
(813) 927-7566

Documents

Posted documents for Sources Sought 36C24826Q0892

Opportunity Assistant


AI Analysis

AI Generate

Incumbent or Similar Awards

Potential Bidders and Partners

Awardees that have won contracts similar to Sources Sought 36C24826Q0892

Similar Active Opportunities

Open contract opportunities similar to Sources Sought 36C24826Q0892

Experts for Geriatric & Decon Manikins

Recommended subject matter experts available for hire

Additional Details

Source Agency Hierarchy
VETERANS AFFAIRS, DEPARTMENT OF > VETERANS AFFAIRS, DEPARTMENT OF > 248-NETWORK CONTRACT OFFICE 8 (36C248)
FPDS Organization Code
3600-00248
Source Organization Code
100167097
Last Updated
July 1, 2026
Last Updated By
michael.shook@va.gov
Archive Date
July 28, 2026