Search Contract Opportunities

Development and Validation of a Magnetocorticography Array using Optimized Optically Pumped Magnetometers

ID: 75N98026Q00778 • Type: Presolicitation • Match:  85%
Opportunity Assistant

Hello! Please let me know your questions about this opportunity. I will answer based on the available opportunity documents.

Please sign-in to link federal registration and award history to assistant. Sign in to upload a capability statement or catalogue for your company

Popular Questions:
Generate a draft:
Loading

Description

Attachment One: Notice of Intent to Sole Source

Background
The National Institutes of Health (NIH) intends to negotiate and award a contract without providing for full and open competition to FieldLine Medical, located at 371 Centennial Parkway, Suite 100, Louisville, CO 80027. This contract is aimed at developing and validating a Magnetocorticography Array using optimized optically pumped magnetometers (OPMs).

The project focuses on creating a high-density array of sensors for improved spatial resolution in brain function mapping, serving as a noninvasive alternative to electrocorticography (ECoG). Previous development activities have been conducted in collaboration with FieldLine Medical, which has proprietary technology essential for the project's success.

Work Details
The contract will involve the design, fabrication, and evaluation of an optimized OPM gradiometer sensor specifically engineered for high-resolution cortical mapping. The prototype gradiometer sensors must be compatible with the existing generation-2 prototype system developed by FieldLine Medical.

The project requires specialized research and development services, including the fabrication and testing of a prototype gradiometer array. Key specifications include:
- Development of a higher-density sensor array
- Integration with existing generation-2 prototype systems
- Use of proprietary components from FieldLine Medical.

Place of Performance
Bethesda MD 20892 UNITED STATES

Bidder Requirements
The contractor must have prior experience with FieldLine Medical's technology and components due to the proprietary nature of the existing systems. No other specific bidder requirements were mentioned.

Overview

Response Deadline
July 23, 2026, 9:00 a.m. EDT Due in 9 Days
Posted
July 13, 2026, 9:09 a.m. EDT
Set Aside
None
Place of Performance
Bethesda, MD 20892 United States
Source

Current SBA Size Standard
1000 Employees
Pricing
Likely Fixed Price
Est. Level of Competition
Sole Source
Est. Value Range
Experimental
$250,000 - $750,000 (AI estimate)
Odds of Award
30%
On 7/13/26 NIH Office of Logistics and Acquisition Operations issued Presolicitation 75N98026Q00778 for Development and Validation of a Magnetocorticography Array using Optimized Optically Pumped Magnetometers due 7/23/26. The opportunity was issued full & open with NAICS 334516 and PSC 6515.
Primary Contact
Name
FALZONE, MICHAEL L   Profile
Phone
None

Documents

Posted documents for Presolicitation 75N98026Q00778

Opportunity Assistant


AI Analysis

AI Generate

Incumbent or Similar Awards

Contracts Similar to Presolicitation 75N98026Q00778

Potential Bidders and Partners

Awardees that have won contracts similar to Presolicitation 75N98026Q00778

Similar Active Opportunities

Open contract opportunities similar to Presolicitation 75N98026Q00778

Experts for Development and Validation of a Magnetocorticography Array using Optimized Optically Pumped Magnetometers

Recommended subject matter experts available for hire

Additional Details

Source Agency Hierarchy
HEALTH AND HUMAN SERVICES, DEPARTMENT OF > NATIONAL INSTITUTES OF HEALTH > NATIONAL INSTITUTES OF HEALTH OLAO
FPDS Organization Code
7529-75N980
Source Organization Code
100189057
Last Updated
July 13, 2026