Description

Background
The U.S. Army Corps of Engineers (USACE), New England District (NAE) intends to procure specialized hydraulic and electronic components for the Stamford Hurricane Barrier Control System Replacement project in Stamford, Connecticut.

This barrier is a critical life-safety infrastructure asset that provides tidal flood and storm surge protection to Stamford and surrounding communities. The contract aims to rehabilitate, modernize, and integrate control systems for existing Hydraulic Power Units (HPUs) and hydraulic manifold assemblies.

Work Details
The project requires the purchase and installation of brand-name components from manufacturers including Bosch Rexroth, HYDAC, Des-Case, Honeywell (Sensotec), Dwyer Omega, and Lisle Corporation.

Key tasks include:
1. Direct integration with existing HPU structures designed by Rexroth, ensuring compatibility with proprietary hydraulic flow paths and mechanical configurations.
2. Installation of components that ensure synchronized operation of the barrier's gate cylinders to prevent mechanical failure.
3. Replacement parts include various valves, filters, sensors, and adapters essential for maintaining system reliability and performance under strict safety standards.

Place of Performance
Stamford CT UNITED STATES

Bidder Requirements
Bidders must demonstrate the ability to provide alternative components that meet critical salient characteristics such as mechanical footprint, flow-gain curves, porting, and sensor scaling without compromising operational safety or synchronization of the barrier. Specific requirements include experience with brand-name components listed in the solicitation.

Notice of Intent for Stamford Hurricane Barrier Control Systems Replacement Mechanical & Hydraulic Components

Under the authority of RFO 6.103-1, the U.S. Army Corps of Engineers (USACE), New England District (NAE) intends to require, on a brand-name basis, the purchase and installation of highly specialized hydraulic and electronic components for the upcoming Stamford Hurricane Barrier Control System Replacement project in Stamford, Connecticut.

The Stamford Hurricane Barrier is a critical life-safety public infrastructure asset providing immediate tidal flood and storm surge protection to the City of Stamford and surrounding communities. The brand-name components specified herein are manufactured by:

  1. Bosch Rexroth
  2. HYDAC
  3. Des-Case
  4. Honeywell (Sensotec)
  5. Dwyer Omega
  6. Lisle Corporation

These components are required for the rehabilitation, modernization, and control integration of the existing main Hydraulic Power Units (HPUs) and hydraulic manifold assemblies.

The use of these brand-name components is essential to meet the Government's strict safety, compatibility, and performance requirements for the following reasons:

  1. The project requires direct integration with the existing HPU structures and manifolds, which were originally designed and manufactured by Rexroth. The new components must be fully compatible with the existing proprietary hydraulic flow paths, mechanical port configurations, and pressure curves.
  2. The barrier's two massive gate cylinders must operate in perfect synchronization to prevent twisting, binding, and potential catastrophic mechanical failure. The specified Bosch Rexroth proportional and counterbalance valves possess proprietary flow-gain curves and spool alignments that are essential to ensure this synchronized movement. Using any other manufacturer's valves would introduce a mismatch, inducing severe structural stress on the barrier.
  3. The existing manifolds are machined with proprietary Rexroth cavity and mounting standards. Generic commercial valves and filters will not seat properly without custom adapters, which would introduce leak paths and degrade system reliability. The specified components ensure a precise physical fit within the existing infrastructure.

Schedule of Intended Brand-Name Components

To afford industry full visibility to review and provide feedback, the intended schedule of brand-name components is itemized below by contract drawing schedules:

  1. HPU Replacement Parts

Quantities reflect the complete project scope across both East and West Abutment HPUs (2 HPUs total).

Tech Pos

Description / Function

Manufacturer

Specified Model / Part Number

Qty / HPU

Total Project Qty

12

3/4" Square-Head Magnetic Trap Plug

Lisle Corporation

Part No. 4054121

2

4

20

Float Level Switch Assembly

Bosch Rexroth

Model 800PUA31-05 3 SW (Part No. R978835263)

2

4

25

Reservoir Filler Connection / Cap

Bosch Rexroth

Model F/ELF5-10-2.0 PUA42-11 (Part No. 97884631)

2

4

30

Desiccant Breather & Mounting Adapter

Des-Case

Breather DC/CS-4 & Adapter DC-12 (Part Nos. R978839894 / R978840030)

2

4

35

Temperature Switch

Bosch Rexroth

Model TEMP SW PUA31-30B E55-14103 (Part No. 97888127)

2

4

40

Bulbwell Steel (11.44" Long)

Bosch Rexroth

Model BULBWELL 11.44 LG PUA31-22 (Part No. R978802575)

2

4

43

Temperature Transducer (RTD)

Dwyer Omega

Model PR-12-2-100-1/4-12-E

2

4

44

Bulbwell for Temperature Transducer

Dwyer Omega

Model 3/4-260S-U10

2

4

45

Bimetal Thermometer

Bosch Rexroth

Model BIMET PUA31-14 WIKA 33X0278 (Part No. 978804856)

2

4

50

Bulbwell Steel (5.25" Long)

Bosch Rexroth

Model BULBWELL 5.25 LG PUA31-22 (Part No. 978804619)

2

4

75

High-Pressure Filter Assembly

HYDAC

Model DF BH/HC 330 T F 10 D 1.0 /-L110-B6 (Part No. 1250576)

2

4

77

Return Line Filter Assembly

HYDAC

Model RF BN/HC 30 B B 10 D 1.0 /-L110 (Part No. 1266488)

2

4

80

3/4" Check Valve (0.5 bar cracking)

Bosch Rexroth

Model S15A05-1X/420/12

4

8

85

1-1/2" Check Valve (0.5 bar cracking)

Bosch Rexroth

Model S30A05-1X/420/12 (Part No. R901454196)

4

8

93

Low-Pressure Gauge Assembly

Bosch Rexroth

Model GSA 4/400PUA31-10A (Part No. 978837831)

2

4

95

High-Pressure Gauge Assembly

Bosch Rexroth

Model GSA 4/3000PUA31-10A (Part No. 978837833)

2

4

110

Direct-Operated Relief Valve

Bosch Rexroth

Model DBDS15G1X/50-12 (Part No. 900534613)

2

4

120

Pilot-Operated Relief Valve

Bosch Rexroth

Model DBW15BG2-5X/315-6EW110N9K4/12 (Part No. 978917231)

2

4

  1. Manifold Wearable Components

Quantities reflect the complete project schedule for the dual-cylinder manifold assemblies.

Item / Tech Pos

Description / Function

Manufacturer

Specified Model / Part Number

Manifold Schedule Qty

201.1

High-Pressure Transducer (0 2000 psi)

Honeywell (Sensotec)

Model Sensotec AP415DL (Part No. 60-F499-01)

6

203.1

Low-Pressure Transducer (0 500 psi)

Honeywell (Sensotec)

Model Sensotec AP415CR (Part No. 60-F441-01)

2

219

Directional Valve

Bosch Rexroth

Model 4WE6D5X/AW120-60NDA/5 (Proportional directional valve w/ OBE)

2

220

Proportional Directional Valve

Bosch Rexroth

Model 4WRZ16-15005X/6A24N9TD3/M-116 (Proportional directional valve w/ OBE)

2

223

Pressure Compensator

Bosch Rexroth

Model ZDC16P-2X/M (Part No. R900489668)

2

225

Counterbalance Valve

Bosch Rexroth

Model FD25KA2X/B04/12 (Part No. R900518087)

2

Salient Characteristics and Technical Rationales

The use of the specified brand-name components is essential to meet the Government's strict life-safety, mechanical synchronization, fluid cleanliness, and physical compatibility requirements.

  1. Bosch Rexroth (Hydraulic Valves, Controls, and Switches):
    • The existing HPUs and distribution manifold blocks were originally engineered and machined to proprietary Rexroth cavity and porting standards. Replacement valves must drop directly into existing cavities without adapter plates, which introduce leak paths and structural compliance issues.
    • The barrier gate is actuated by two massive hydraulic cylinders on opposite sides of the navigational opening. These cylinders must operate in strict displacement and velocity synchronization to prevent mechanical twisting, binding, and structural failure. Rexroth proportional (Item 220) and counterbalance valves (Item 225) possess proprietary flow-gain curves, matched spool alignments, and factory-calibrated on-board electronics (OBE) essential to maintaining synchronized motion.
  2. HYDAC (Pressure and Return Line Filtration):
    • The close-tolerance proportional valves require hydraulic fluid (Mobil DTE 10 Excel 32) maintained strictly at ISO 4406 cleanliness rating 17/15/12. HYDAC Betamicron filter elements provide the validated single-pass Beta ratio ( 10(c) 1000) required to prevent spool erosion and sticking.
    • The filter assemblies match existing piping brackets and incorporate integral clogging indicators (110V/B6 signal outputs) that wire directly into the PLC input modules.
  3. Des-Case (Desiccant Breathers & Adapters):
    • In a harsh marine environment, humid and salt-laden air entering the reservoir causes rapid oil emulsification and valve corrosion. Des-Case DC/CS-4 breathers utilize high-efficiency silica gel media coupled with 3-micron particulate filtration and bi-directional internal check valves.
    • The DC-12 quick-flange adapter interfaces directly with existing reservoir cover plates, providing a hermetic, vibration-proof seal without field drilling or hot-work near oil reservoirs.
  4. Honeywell Sensotec (Precision Pressure Transducers):
    • The automated control system monitors real-time cylinder pressure to balance load sharing and detect hydraulic stalls. Honeywell Sensotec AP415DL and AP415CR transducers are electrically matched to the scaling tables and signal registers programmed into the PLC analog cards.
    • Feature high-pressure flush-diaphragm threaded connections engineered to seal into existing Rexroth manifold sensor cavities without pipe-thread adapters.
  5. Dwyer Omega (Temperature Transducers / RTDs):
    • Cold hydraulic oil degrades proportional valve response time. The Dwyer Omega PR-12E RTD temperature sensor monitors reservoir fluid temperature to manage immersion heaters and prevent barrier deployment when fluid viscosity exceeds safe operating thresholds.
    • Features 1/4" NPT threads and probe immersion dimensions matching existing reservoir thermowells.
  6. Lisle Corporation (Magnetic Reservoir Trap Plugs):
    • Captures recirculating microscopic ferrous wear particles that escape surface filters, protecting high-pressure pump pistons and valve spools.
    • Engineered with heavy-duty 3/4" square-head profiles that seat into existing tank cleanout ports and resist stripping during routine maintenance.

Submission of Capabilities:

THIS IS A NOTICE OF INTENT, NOT A REQUEST FOR COMPETITIVE PROPOSALS OR A SOLICITATION. A solicitation will be issued at a later date.

However, any firm that believes it can provide alternative components that meet all the critical salient characteristics (e.g., mechanical footprint, flow-gain curves, porting, sensor scaling) and can demonstrate how using such components would not compromise the operational safety and synchronization of the Stamford Hurricane Barrier may submit a capability statement.

This notice is a market research tool being used to determine the availability of other qualified sources that can meet the requirements identified above. The Government is not obligated to and will not pay for any information received because of this notice. All responses received within 15 days of the posting of this notice will be considered by the Government. A determination by the Government to require the specified brand names is solely within the discretion of the Government.

Submit responses within 15 days of the posting of this notice of intent via email to: Distephano.Marcellus@usace.army.mil (list W912WJ27BA001 Stamford Hurricane Barrier Mechanical Components in the subject line of the email).

Loading Map
Loading Map

Overview

Response Deadline
Due in 14 Days
Posted
Set Aside
None
Place of Performance
Stamford, CT United States
Source

Current SBA Size Standard
$19 Million
Pricing
Likely Fixed Price
Est. Value Range
Experimental
$400,000 - $1,200,000 (AI estimate)
On 9/17/26 USACE New England District issued Special Notice for Control System Replacement for Stamford Hurricane Barrier, Stamford, CT due 10/2/26.
Primary Contact
Name
Distephano Marcellus   Profile
Phone
(978) 318-8890

Documents

Posted documents for Control System Replacement for Stamford Hurricane Barrier, Stamford, CT

Opportunity Assistant


Analyze Opportunity

Generate a Draft

IDV Awards

Indefinite delivery vehicles awarded through Control System Replacement for Stamford Hurricane Barrier, Stamford, CT

Contract Awards

Prime contracts awarded through Control System Replacement for Stamford Hurricane Barrier, Stamford, CT

Protests

GAO protests filed for Control System Replacement for Stamford Hurricane Barrier, Stamford, CT

Incumbent or Similar Awards

Contracts Similar to Control System Replacement for Stamford Hurricane Barrier, Stamford, CT

Potential Bidders and Partners

Awardees that have won contracts similar to Control System Replacement for Stamford Hurricane Barrier, Stamford, CT

Similar Active Opportunities

Open contract opportunities similar to Control System Replacement for Stamford Hurricane Barrier, Stamford, CT

Experts for Control System Replacement for Stamford Hurricane Barrier, Stamford, CT

Recommended subject matter experts available for hire

Additional Details

Source Agency Hierarchy
DEPT OF DEFENSE > DEPT OF THE ARMY > USACE > NAD > W2SD ENDIST NEW ENGLAND
FPDS Organization Code
2100-W912WJ
Source Organization Code
100221388
Last Updated
Last Updated By
distephano.marcellus@usace.army.mil
Archive Date