Search Contract Opportunities

Commercial Diesel Generator Set, 600kW Standby 60Hz

ID: W911S226U3180 • Type: Synopsis Solicitation • Match:  85%
Opportunity Assistant

Hello! Please let me know your questions about this opportunity. I will answer based on the available opportunity documents.

Please sign-in to link federal registration and award history to assistant. Sign in to upload a capability statement or catalogue for your company

Popular Questions:
Generate a draft:
Loading

Description

Posted: May 7, 2026, 8:00 a.m. EDT
Amended to include set aside code. Characteristics:600DQCA, Diesel Genset, 60Hz, 600kW, Duty Rating - Standby Power (ESP), Emission Certification, EPA, Tier 2, NSPS CI Stationary Emergency, Listing- UL 2200, Voltage - 277/480, 3 Phase, Wye, 4 Wire, Alternator - 60Hz, Wye, 480 Volts,105C ? Standby, Alternator Heater, 120 Volt AC, Steel Sound Attenuated Level 2Enclosure, with Exhaust System, Enclosure Color - Green, Steel, Cooling Air Outlet -Horizontal, Sound Attenuated, Louvers - Air Inlet, 24 Volts DC Spring Closed, Motor Opened, Louvers - Air Outlet, 24 Volts DC Spring Closed, Motor Opened, Distribution Panel - Prewired AC Features, Fuel Tank - Sub Base, 2400 Gallon, UL142 Compliant, Listing, ULC - S601 ? 07, Alarm - High Fuel Fill, Fuel Tank Connection - Dual Stub Up,Fuel Water Separator, Control Mounting - Left Facing, Power Command 2.3 Controller, LCD Control Display, Stop Switch - Emergency, Externally Mounted, Signals - Auxiliary,8 Inputs/8 Outputs, Control Display Language ? English, Circuit Breaker or Entrance Boxor Terminal Box - Right Only, Terminal Box- Low Voltage, Left- None, Circuit Breaker -1200A, Right, 3P, UL 600, IEC 415, UL Serv Ent, 100%, Circuit Breaker or Entrance Boxor Terminal Box, Top Entry, Left- None, Bottom Entry, Right, Engine Air Cleaner - Normal Duty, External Battery Charger - 12 Amp, Regulated, Engine Cooling - Radiator, 50CAmbient, Shutdown - Low Coolant Level, Coolant Heater - 208/240/480 Volts AC, Below40F Ambient Temperature, Genset Warranty - 2 Years Base, Literature ? English, Packing -None, Base Mounted Housing, OTECD, OTEC Transfer Switch- Electronic Control:
Posted: May 6, 2026, 1:45 p.m. EDT
Background
This solicitation is issued by the U.S. Army for a commercial product, specifically a diesel generator set. The purpose of this contract is to procure a 600kW standby diesel generator that meets specific technical requirements and standards set forth by the agency. The contract is part of a Total Small Business Set-Aside initiative, encouraging small businesses to participate in government contracting.

Work Details
The contract involves the delivery of one (1) Commercial Diesel Generator Set with the following salient characteristics:
- Model: 600DQCA
- Power Output: 600kW Standby, 60Hz
- Duty Rating: Standby Power (ESP)
- Emission Certification: EPA Tier 2, NSPS CI Stationary Emergency
- Listing: UL 2200
- Voltage: 277/480, 3 Phase, Wye, 4 Wire
- Alternator Specifications: 60Hz, Wye, 480 Volts, 105C Standby
- Enclosure: Steel Sound Attenuated Level 2 with Exhaust System, Color - Green
- Fuel Tank: Sub Base, 2400 Gallon, UL142 Compliant
- Control System: Power Command 2.3 Controller with LCD Control Display
- Circuit Breaker: 1200A, Right, 3P, UL 600
- Warranty: Genset Warranty - 2 Years Base. The generator must be new equipment only; used or remanufactured products will not be accepted.

Place of Performance
F.O.B. destination; specific delivery locations are not detailed in the solicitation.

Overview

Response Deadline
May 13, 2026, 2:00 p.m. EDT Due in 5 Days
Posted
May 6, 2026, 1:45 p.m. EDT (updated: May 7, 2026, 8:00 a.m. EDT)
Set Aside
Small Business (SBA)
Place of Performance
4525 Camp Hale Rd Fort Drum, NY 13602 Fort Drum, NY 13602 USA
Source

Current SBA Size Standard
1250 Employees
Pricing
Fixed Price
Est. Level of Competition
Average
Est. Value Range
Experimental
$250,000 - $450,000 (AI estimate)
Signs of Shaping
The solicitation is open for 7 days, below average for the MICC Fort Drum. 93% of obligations for similar contracts within the Department of the Army were awarded full & open.
On 5/6/26 MICC Fort Drum issued Synopsis Solicitation W911S226U3180 for Commercial Diesel Generator Set, 600kW Standby 60Hz due 5/13/26. The opportunity was issued with a Small Business (SBA) set aside with NAICS 335312 (SBA Size Standard 1250 Employees) and PSC 6115.
Primary Contact
Name
Carrie Lawton   Profile
Phone
7721065

Documents

Posted documents for Synopsis Solicitation W911S226U3180

Opportunity Assistant


AI Analysis

AI Generate

Incumbent or Similar Awards

Contracts Similar to Synopsis Solicitation W911S226U3180

Potential Bidders and Partners

Awardees that have won contracts similar to Synopsis Solicitation W911S226U3180

Similar Active Opportunities

Open contract opportunities similar to Synopsis Solicitation W911S226U3180

Experts for Commercial Diesel Generator Set, 600kW Standby 60Hz

Recommended subject matter experts available for hire

Additional Details

Source Agency Hierarchy
DEPT OF DEFENSE > DEPT OF THE ARMY > AMC > ACC > MISSION & INSTALLATION CONTRACTING COMMAND > 419TH CSB
FPDS Organization Code
2100-W911S2
Source Organization Code
500036690
Last Updated
May 7, 2026
Last Updated By
carrie.l.lawton.civ@army.mil
Archive Date
May 7, 2027