Description

PLEASE SEE ATTACHMENTS FOR ADDITIONAL INFORMATION REGARDING THIS REQUIREMENT

Notice Type: Sources Sought (MARKET RESEARCH PURPOSES ONLY)
Title: Secure Facility Chilled Water System Replacement Federal Installation, CO
NAICS Code: 238220 Plumbing, Heating, and Air-Conditioning Contractors
Product Service Code (PSC): N041 Installation of Equipment: Refrigeration, Air Conditioning, and Air Circulating Equipment
Response Date: 22 July 2026

Description:

The Department of the Air Force (DAF), on behalf of the Base Civil Engineer Squadron (CES) at a Federal Installation in Colorado, is conducting market research to identify qualified, experienced, and interested business sources specifically targeting small and socio-economic businesses (e.g., 8(a), SDVOSB, HUBZone, WOSB) capable of performing a complete chilled water system replacement in a 24/7 operations facility.

Project Objective: The chilled water system serving the facility's server room currently suffers from degraded serviceability, sub-component failures, and frequent downtime. It is operating at half capacity, which risks the loss of critical cooling for 24/7 operations. The selected contractor must provide all tools, equipment, materials, and certified labor to perform a complete system replacement with zero downtime to the active server room.

Key Scope Items & Technical Specifications:

  1. Design & Sizing: Perform professional engineering cooling system design load calculations in accordance with UFC 3-410-01 (Sections 2-4 and 2-5.6) to determine final system capacity.
  2. Standardization Requirement: In accordance with the DAF Class Justification and Approval (J&A) for HVAC Chiller Replacement Standardization, the design of the new chiller system must be standardized on Trane-series equipment for this installation.
  3. Demolition: Safely decommission, recover refrigerant from, and remove the existing degraded chiller (Technical Systems Model: 30A0LM20-PT, Serial: 02-17-125822-001-001) and two existing Computer Room Air Handlers (CRAHs) (Data Aire Model: GFCU-04634, Serials: 2016-3226-A, 20163225-A).
  4. Equipment Installation: Procure, install, and commission:
    • One (1) new water chiller with an integrated air-cooled condenser (Trane-series).
    • Two (2) new chilled-water Computer Room Air Handlers (CRAHs) inside the secure server room.
  5. Temporary Cooling: Provide continuous, redundant temporary cooling to keep the secure server room strictly within operational temperature limits during the transition phase.
  6. Controls Integration: Fully integrate new controls into the base-wide Energy Management Control System (EMCS) in strict compliance with Base EMCS Standards (dated January 21, 2026) and UFC 3-410-02.

Logistical & Physical Constraints:

  • Chiller Pad Limits: The new chiller must fit the existing concrete pad (19' - 11 L x 12'- 8 W x 6 to 8 H) and must not exceed the structural wet weight limit of 12,000 lbs. If the equipment footprint exceeds these limits, the pad must be extended.
  • Rigging & Delivery Clearances: CRAHs must be navigated through a restricted interior corridor with doorway clearances measuring exactly 34 W x 82 H.
  • Electrical: Must integrate with the existing 460V, 60 Hz, 3-Phase power supply and comply with UFC 3-501-01.
  • Security & Clearances: All personnel must pass NCIC background checks, comply with strict OPSEC guidelines, and complete AT Level I training prior to facility access.

Overview

Response Deadline
July 22, 2026, 3:00 p.m. EDT Due in 7 Days
Posted
July 14, 2026, 12:18 p.m. EDT
Set Aside
Small Business (SBA)
Place of Performance
Aurora, CO 80011 United States
Source

Current SBA Size Standard
$19 Million
Pricing
Likely Fixed Price
Odds of Award
37%
Signs of Shaping
The solicitation is open for 8 days, below average for the Space Force.
On 7/14/26 Space Force issued Sources Sought BuckleySFBChillerReplacement for Buckley SFB Chiller Replacement due 7/22/26. The opportunity was issued with a Small Business (SBA) set aside with NAICS 238220 (SBA Size Standard $19 Million) and PSC N041.
Primary Contact
Name
Ethan Sullivan   Profile
Phone
(720) 847-6446

Documents

Posted documents for Sources Sought BuckleySFBChillerReplacement

Opportunity Assistant


AI Analysis

AI Generate

Incumbent or Similar Awards

Potential Bidders and Partners

Awardees that have won contracts similar to Sources Sought BuckleySFBChillerReplacement

Similar Active Opportunities

Open contract opportunities similar to Sources Sought BuckleySFBChillerReplacement

Experts for Buckley SFB Chiller Replacement

Recommended subject matter experts available for hire

Additional Details

Source Agency Hierarchy
DEPT OF DEFENSE > DEPT OF THE AIR FORCE > AFSPC > FA2543 460 CONS
FPDS Organization Code
5700-FA2543
Source Organization Code
100076523
Last Updated
July 14, 2026
Last Updated By
ethan.sullivan@spaceforce.mil
Archive Date
Aug. 6, 2026