B103 Repair Mechanical Systems and Building Improvements

ID: N40080-24-R-3956 • Type: Solicitation • Match:  90%
Opportunity Assistant

Hello! Please let me know your questions about this opportunity. I will answer based on the available opportunity documents.

Please sign-in to link federal registration and award history to assistant. Sign in to upload a capability statement or catalogue for your company

Popular Questions:
Generate a draft:
Loading

Description

The project includes but is not limited to replacement of deteriorating (27) hydronic floor mounted fan coil units to include associated fittings, piping, valves, and accessories. (2) 7.5 ton rooftop package units to include associated, disconnect switches, circuit breakers, conduits, wirings, piping, valves, temperature sensors, controls, and accessories. (2) Mini-split type a/c unit to include associated disconnect switches, circuit breakers, conduits, wirings, piping and accessories located in IDF room and locker room. (4) Ceiling exhaust fans and associated accessories located in first floor toilet male and female rooms, locker room, and weather office room 104. (1) Baseboard heater unit and associated accessories located in second floor corridor 100 entryway.

The new work includes of the following:

1) Provide and install (27) new ceiling cassette type fan coil units to include associated fittings,

valves, piping, insulation, hanger support, digital control, and accessories. Provide fan coil units

that match the existing chiller unit brand.

2) Modify existing fan coil units piping (cold/hot) as required for proper installation of new ceiling cassette type units. Remove any unused piping, fittings, valves, and associated accessories. Where required, drywall is removed add layer of 1 2 rigid expanded polystyrene (EPS) foam.

3) Provide and install (2) new 7.5 ton rooftop package units to include associated, disconnect

switches, circuit breakers, conduits, wirings, piping, valves, temperature sensors, digital controls,

and accessories. Provide necessary equipment required for ductwork cleaning. At no time both

units will be down. Provide and install (2) pole metal mounted for disconnect switches.

4) Provide and install new (2) mini-split type a/c unit with cooling only to include associated

disconnect switches, circuit breakers, conduits, wirings, piping and accessories located in IDF

room and locker room. Existing housekeeping pads may reused if good condition is acceptable.

5) Provide and install new (4) ceiling exhaust fans located in first floor toilet male and female rooms, locker room, and weather office room 104.

6) Provide and install new baseboard heater unit and associated accessories located in second floor corridor 100 entryway.

7) Provide and install new ceiling exhaust fan in second floor room 205; shower and toilet rooms to include circuit breakers, conduits, wirings, and associated accessories.

8) Provide and install new dedicated outdoor air system (DOAS) unit to include associated

ductwork, housekeeping pad, disconnect switch, circuit breakers, conduits, wirings, control,

sensors, and accessories. Provide design for DOAS unit to include ductwork and electrical

systems. Perform load calculation to determine appropriate size unit.

9) Provide and install new acoustical ceiling tiles and associated accessories that match the existing patterns and finishes.

10) Modify existing electrical panel to adapt serve new DOAS unit and ceiling exhaust fans.

Existing electrical wiring may reused if capacity is adequate and in good condition.

Building will remain occupied during construction. Very important, heating, cooling, and dehumidification shall be maintained in the Air Traffic control operation room during this project.

Background
The project is titled B103 Repair Mechanical Systems and Building Improvements and is located at B103 Naval Air Station, Patuxent River, MD. The project includes the replacement of deteriorating hydronic floor mounted fan coil units, rooftop package units, mini-split type a/c units, ceiling exhaust fans, and baseboard heater unit. The work also involves the installation of new ceiling cassette type fan coil units, modification of existing fan coil units piping, installation of new 7.5 ton rooftop package units, mini-split type a/c unit, ceiling exhaust fans, baseboard heater unit, ceiling exhaust fan in second floor room 205, dedicated outdoor air system (DOAS) unit, and acoustical ceiling tiles.
The building will remain occupied during construction with a focus on maintaining heating, cooling, and dehumidification in the Air Traffic control operation room.

Work Details
The work includes the installation of various mechanical systems and building improvements such as fan coil units, rooftop package units, mini-split type a/c units, exhaust fans, baseboard heater unit, dedicated outdoor air system (DOAS) unit, and acoustical ceiling tiles. It also involves modifying existing electrical panels to adapt to the new DOAS unit and ceiling exhaust fans.
The estimated budget for the design build is $1,371,000.
The project is expected to be completed within 305 calendar days after award.

Place of Performance
The construction projects will be performed at B103 Naval Air Station, Patuxent River, MD.

Overview

Response Deadline
June 3, 2024, 2:00 p.m. EDT Past Due
Posted
May 3, 2024, 9:46 a.m. EDT
Set Aside
None
Place of Performance
Patuxent River, MD 20670 United States
Source

Current SBA Size Standard
$45 Million
Pricing
Likely Fixed Price
Est. Level of Competition
Average
Est. Value Range
Experimental
$150 - $0 (AI estimate)
On 5/3/24 Naval Facilities Engineering Command issued Solicitation N40080-24-R-3956 for B103 Repair Mechanical Systems and Building Improvements due 6/3/24. The opportunity was issued full & open with NAICS 236220 and PSC Z2AA.
Primary Contact
Name
Jennifer Bowling   Profile
Phone
(202) 538-4189

Secondary Contact

Name
Keetje Straub   Profile
Phone
(202) 735-4002

Documents

Posted documents for Solicitation N40080-24-R-3956

Opportunity Assistant


AI Analysis

AI Generate

Incumbent or Similar Awards

Contracts Similar to Solicitation N40080-24-R-3956

Potential Bidders and Partners

Awardees that have won contracts similar to Solicitation N40080-24-R-3956

Similar Active Opportunities

Open contract opportunities similar to Solicitation N40080-24-R-3956

Experts for B103 Repair Mechanical Systems and Building Improvements

Recommended subject matter experts available for hire

Additional Details

Source Agency Hierarchy
DEPT OF DEFENSE > DEPT OF THE NAVY > NAVFAC > NAVFAC ATLANTIC CMD > NAVFAC WASHINGTON > NAV FAC ENGINEERING CMD WASHINGTON
FPDS Organization Code
1700-N40080
Source Organization Code
100076577
Last Updated
June 18, 2024
Last Updated By
jennifer.bowling@navy.mil
Archive Date
June 18, 2024