611 CES Wheeler B310 Fire Suppression System Testing

ID: FA521526Q0053 • Type: Solicitation • Match:  85%
Opportunity Assistant

Hello! Please let me know your questions about this opportunity. I will answer based on the available opportunity documents.

Please sign-in to link federal registration and award history to assistant. Sign in to upload a capability statement or catalogue for your company

Analyze Opportunity
Generate a Draft
Loading

Description

Background
The United States Air Force, specifically the 766th Enterprise Sourcing Squadron at Joint Base Pearl Harbor-Hickam, Hawaii, is issuing this contract to secure certified technical services for the fire suppression and alarm systems at Building 310 on Wheeler Air Force Station.

The primary goal is to address compliance issues identified in a recent Fire Department assessment, which noted that inspection, testing, and maintenance (ITM) of the sprinkler system has not been performed since 2016, and the Fire Alarm Control Panel (FACP) is displaying a 'trouble' status. This contract aims to ensure that all fire protection systems are fully operational and compliant with relevant safety standards.

Work Details
The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, and supervision necessary to perform troubleshooting, comprehensive inspection, maintenance, and certification of the fire suppression and FACP systems at Building 310.

Key tasks include:
1. Troubleshooting the FACP to diagnose the cause of the 'trouble' status and executing necessary repairs.
2. Performing comprehensive visual and mechanical inspections for Sprinkler ITM dating back to 2016, including mandatory annual tests per NFPA 25.
3. Verifying system integration with central FACP and base fire department notification systems during simulated trigger events.
4. Updating physical tags on the system to reflect current inspection dates and technician credentials.
5. Adhering to protocols for system impairments or outages during testing or repairs to prevent accidental emergency responses.

Place of Performance
Building 310 at Wheeler Air Force Station, Oahu, HI.

Bidder Requirements
Bidders must meet the following requirements: Small Business Set Aside - Total (SBA), possess necessary certifications for fire protection services, have relevant experience in fire suppression system maintenance and repair as outlined in DAFMAN 91-203 and UFC 3-601-02 standards.

Incumbent Analysis (see Incumbents section for more detail)
This opportunity appears to have a confirmed incumbent and/or closely related prior contract based on FA521524C0039, awarded to Media Plumbing & Heating for $71,673 (09/27/24–09/26/29). That prior work required inspection, testing, maintenance, and minor repairs of fire alarm control panels/detectors and automated fire sprinkler systems, which aligns closely with the current requirement to troubleshoot the FACP “trouble” condition and complete lapsed sprinkler and alarm ITM cycles for Building 310. The scope also reads like an extension of ongoing ITM/certification activities rather than a substantially different service line.

The objective of this contract is to secure certified technical services to troubleshoot the FACP, perform all lapsed ITM cycles, repair identified deficiencies, and fully recertify the system. All inspection, testing, maintenance, and repair of the fire suppression and detection systems shall be performed in strict accordance with DAFMAN 91-203, Chapter 6 (Fire Protection and Life Safety), and UFC 3-601-02 (Fire Protection Systems Inspection, Testing, and Maintenance).

The primary fire suppression and alarm systems for Building 310 at Wheeler Air Force Station are currently out of compliance. A recent Fire Department assessment identified that Sprinkler Inspection, Testing, and Maintenance (ITM) has not been accomplished since 2016, and the Fire Alarm Control Panel (FACP) ITM has lapsed and is actively displaying a "trouble" status.

Quotes are due by 8:00 AM HST September 24, 2026.

Reference the attached documents;

1. Performance Work Statement

2. Provisions and Clauses

3. Additional Clauses

4. SCA Wage Determination

5. Itemized Price List

6. SF1449

7. RFQ

Point of contact:

Contracting Specialist: A1C Michael R. Perreira michael.perreira.3@us.af.mil 808-789-3167

Contracting Officer: SSgt Thomas Hembree thomas.hembree@us.af.mil 808-789-3170

Loading Map
Loading Map

Overview

Response Deadline
Due in 6 Days
Posted
Set Aside
Small Business (SBA)
Place of Performance
Wahiawa, HI 96786 United States
Source

Current SBA Size Standard
$25 Million
Pricing
Fixed Price
Est. Level of Competition
Average
Est. Value Range
Experimental
$25,000 - $90,000 (AI estimate)
Signs of Shaping
The solicitation is open for 6 days, below average for the Pacific Air Forces. 88% of obligations for similar contracts within the Department of the Air Force were awarded full & open.
On 9/17/26 Pacific Air Forces issued Solicitation FA521526Q0053 for 611 CES Wheeler B310 Fire Suppression System Testing due 9/24/26. The opportunity was issued with a Small Business (SBA) set aside with NAICS 561621 (SBA Size Standard $25 Million) and PSC J012.
Primary Contact
Name
A1C Michael R. Perreira   Profile
Phone
(808) 789-3167

Secondary Contact

Name
SSgt Thomas Hembree   Profile
Phone
(808) 789-3170

Documents

Posted documents for Solicitation FA521526Q0053

Opportunity Assistant


Analyze Opportunity

Generate a Draft

Incumbent or Similar Awards

Contracts Similar to Solicitation FA521526Q0053

Potential Bidders and Partners

Awardees that have won contracts similar to Solicitation FA521526Q0053

Similar Active Opportunities

Open contract opportunities similar to Solicitation FA521526Q0053

Experts for 611 CES Wheeler B310 Fire Suppression System Testing

Recommended subject matter experts available for hire

Additional Details

Source Agency Hierarchy
DEPT OF DEFENSE > DEPT OF THE AIR FORCE > PACAF > FA5215 766 ESS PKP
FPDS Organization Code
5700-FA5215
Source Organization Code
100266671
Last Updated
Last Updated By
michael.perreira.3@us.af.mil
Archive Date