QTY-1EA, Computer Room Air Conditioning (CRAC) unit

ID: 36C26025Q0683 • Type: Sources Sought

Description

DESCRIPTION THIS IS A REQUEST FOR INFORMATION ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this sources sought to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide the following services: Proposed NAICS Code 333415. Any questions or concerns may be directed to Derek Crockett via e-mail at derek.crockett@va.gov. RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION AND RESPONSES TO THE FOLLOWING QUESTIONS: 1.) Company name, address, and business size; point of contact name, phone number, and e-mail address. 2.) Is your firm eligible for participation in one of the following small business programs? If so, please indicate the program and the anticipated North American Industry Classification System (NAICS) code. [ ] yes [ ] no Small Business (SB) [ ] yes [ ] no HUBZone [ ] yes [ ] no Small Business 8(a) [ ] yes [ ] no Small Disadvantaged Business (SDB) [ ] yes [ ] no Women-Owned (WO) Small Business [ ] yes [ ] no Service Disabled Veteran Owned Small Business (SDVOSB) [ ] yes [ ] no Veteran Owned Small Business (VOSB) [ ] yes [ ] no Other (please specify) 3.) Are you a manufacturer or authorized distributor of Computer Room Air Conditioning (CRAC) units? Is yes, what manufacturer(s) and model(s) are you authorized to distribute, and what length of warranty length and terms come with a unit? 4.) What are you estimated lead times for ordering and delivery of QTY1EA CRAC unit? 5.) Does your firm have any existing contracts with the federal government or specific government agencies? (GSA, FSS, ect). If yes, please list the contract number(s) and agency contracts. 6.) Based on the Draft Statement of Work (SOW) and scope of services stated below, what additional information would you need to accurately estimate the effort for this requirement? 7.) Please provide a capability statement (not to exceed 5 pages) detailing any current or historical projects for similar requirements. DRAFT STATEMENT OF WORK (SOW): DRAFT Statement of Work (SOW) - Procurement of CRAC Unit Precision Cooling 1.0 General This Statement of Work (SOW) outlines the requirements for the procurement and delivery of Computer Room Air Conditioning (CRAC) unit. The CRAC unit is required by MANN GRANDSTAFF VA Medical Center Spokane, WA. to replace an aged 25-year-old unit obsolete unit. 2.0 Scope of Work The Vendor shall furnish the latest model CRAC unit, compliant with the specifications outlined in Section 3.0. The scope of work includes, but is not limited to: Procurement: Supply of the specified CRAC units as detailed in the Equipment List (Section 3.1). Delivery: Delivery of the CRAC unit to 4815 N. Assembly Street, Spokane, WA. 99208. Required Delivery Date: 10/01/25. Documentation: Providing all necessary documentation, including but not limited to: Manufacturer's technical data sheets Installation, operation, and maintenance manuals Warranty information 3.0 Equipment List Location Quantity Specifications Design Basis Telecomm Room Building 1 Room B0114A-CRAC 1 2800 CFM, 63 KBTU/HR, at Approx 75F-45%RH 208/60V-3Ph-60Hz, 76.5 FLA., 81.5 WSA,90 OPD, Up flow VERTIV PX018UA1CB 3.1 General Requirements Compliance: The CRAC units shall comply with all applicable ASHRAE, ASME, and UL standards. Systems Details: Up flow with front air return ICOM control with high-definition display ICOM based comms BACnet Variable speed EC plug fans digital scroll variable capacity compressor utilizing environmental approved refrigerant. Evaporator type tilted-slab, cooper tubes, aluminum fins with hydrophilic coating infrared humidification 65,000Amp, rms short circuit current rating locking disconnect switch Dual-float CONDENSATE PUMP FACTORY MOUNTED INTERNAL TO UNIT Filter rating MERV 13 per ASHRAE Supply air sensor Smoke sensor Temperature/humidity sensors internal for return air sensing one remote shut down contact three alarm contacts discharge grill plenum-3 way discharge Point LEAK DETECTION SENSOR Air cooled microchannel condenser/ 208 v/3 PHASE. 60Hz, 2.3FLA,209WSA,15OPD Dimensions: Height: no more than 77 9/16 Width: 34 1 2 Depth:34 5/8 4.0 Deliverables The Contractor shall deliver the following: CRAC units as specified in Section 3.0. All required documentation as outlined in Section 2.0. Equipment shall be secured & packaged for outdoor, uncovered storage until installation. Delivery shall take place at: Delivery of the CRAC unit to 4815 N. Assembly Street, Spokane, WA. 99208. Required Delivery Date: 10/01/25. 5.0 Warranty The CRAC units shall be covered by a comprehensive manufacturer's warranty.
Background
The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources capable of providing Computer Room Air Conditioning (CRAC) units.

This request for information aims to gather insights on the availability and capabilities of qualified contractors to fulfill a requirement for the MANN GRANDSTAFF VA Medical Center in Spokane, WA, which needs to replace an outdated 25-year-old unit.

Work Details
The contract involves the procurement and delivery of one Computer Room Air Conditioning (CRAC) unit with the following specifications:
- Quantity: 1 CRAC unit
- Specifications: 2800 CFM, 63 KBTU/HR at approximately 75°F and 45% RH, powered by 208/60V-3Ph-60Hz. The model required is VERTIV PX018UA1CB.
- Compliance with ASHRAE, ASME, and UL standards is mandatory.
- The unit must feature up flow with front air return, ICOM control with high-definition display, variable speed EC plug fans, digital scroll variable capacity compressor using environmentally approved refrigerant, and various sensors including temperature/humidity sensors and smoke sensors.
- Dimensions must not exceed: Height: 77 9/16”, Width: 34 ½”, Depth: 34 5/8”.
- Delivery location is specified as 4815 N. Assembly Street, Spokane, WA. Required delivery date is set for October 1, 2025.

Period of Performance
Delivery is required by October 1, 2025.

Place of Performance
The product will be delivered to the Department of Veterans Affairs Spokane VA Medical Center located at 4815 N Assembly St, Spokane, Washington.

Overview

Response Deadline
July 18, 2025, 6:00 p.m. EDT (original: July 10, 2025, 6:00 p.m. EDT) Past Due
Posted
June 30, 2025, 1:01 p.m. EDT (updated: July 10, 2025, 7:07 p.m. EDT)
Set Aside
None
Place of Performance
Department of Veterans Affairs Spokane VA Medical Center Spokane 99205
Source
SAM

Current SBA Size Standard
1250 Employees
Pricing
Likely Fixed Price
Est. Level of Competition
Low
Est. Value Range
$4,120 (value based on agency estimated range)
Odds of Award
20%
On 6/30/25 VISN 20: Northwest Network issued Sources Sought 36C26025Q0683 for QTY-1EA, Computer Room Air Conditioning (CRAC) unit due 7/18/25. The opportunity was issued full & open with NAICS 333415 and PSC 4120.
Primary Contact
Title
Contract Specialist
Name
Derek Crockett   Profile
Phone
360-816-2760 x32760

Documents

Posted documents for Sources Sought 36C26025Q0683

Question & Answer

Incumbent or Similar Awards

Potential Bidders and Partners

Awardees that have won contracts similar to Sources Sought 36C26025Q0683

Similar Active Opportunities

Open contract opportunities similar to Sources Sought 36C26025Q0683

Additional Details

Source Agency Hierarchy
VETERANS AFFAIRS, DEPARTMENT OF > VETERANS AFFAIRS, DEPARTMENT OF > 260-NETWORK CONTRACT OFFICE 20 (36C260)
FPDS Organization Code
3600-00260
Source Organization Code
100186526
Last Updated
July 10, 2025
Last Updated By
derek.crockett@va.gov
Archive Date
Aug. 9, 2025