Description

Posted: Feb. 21, 2025, 4:56 p.m. EST

The contractor shall provide all equipment, materials, and labor associated with the removal, disposal, and replacement of the lift station control panel.

On 2/14/2025 a site visit was held at Lock and Dam 2. Four (4) companies showed up for the site visit. There were J3 Enterprice, TPC, Vonco, And Minnesota Pump Works.

02/20/2025- Solication amended to answer questions from industry.

02/21/2025 - Changed Due date for Quotes.

Posted: Feb. 20, 2025, 1:36 p.m. EST
Posted: Feb. 7, 2025, 3:12 p.m. EST
Background
The contract is issued by the U.S. Army Corps of Engineers for the Lock and Dam #2 facility located in Hastings, MN. The mission of this contract is to replace the malfunctioning lift station control panel due to severe corrosion caused by a non-weather-tight enclosure.

The goal is to ensure reliable operation of the septic lift station controls, which are critical for maintaining the functionality of the facility.

Work Details
The contractor shall provide all equipment, materials, and labor necessary for the removal, disposal, and replacement of the lift station control panel at Lock and Dam No. 2. The new installation must include:
- A lockable, NEMA 4X rated stainless steel enclosure.
- A new 120V duplex pump lift station control panel with a humidity control system to prevent future corrosion.
- High Level Alarm System: An alarm system on its own circuit with features to test the alarm float (test/off/norm), an audible/visual alarm with test, silence, and reset features, and an external audible/visual high limit/malfunction alarm (minimum 80 dB visible from 100ft).
- Pump Controls and Indicators: Manual (hand)/off/auto switch for each pump, hour meter for each pump, separate indication lights for pump status, overload reset switches, and an alternating pump switch.
- Float Controls and Indicators: Switches for controlling lag and lead floats as well as a stop float switch.
- Other Features: Main service disconnect (120V 1-phase 60Amp max), a 120V GFCI convenience outlet, thermostat-controlled anti-condensation heater with overcurrent protection, and a minimum of 5 independent circuits with breakers/disconnects for each component (Pump1, Pump2, Alarm, Controls, Outlet).

The contractor must also provide an electrical schematic of installed equipment along with make/model/part numbers.

Period of Performance
30 days after notice to proceed.

Place of Performance
Lock & Dam #2, 1350 Lock and Dam Road, Hastings, MN 55033

Overview

Response Deadline
Feb. 21, 2025, 3:00 p.m. EST Past Due
Posted
Feb. 7, 2025, 3:12 p.m. EST (updated: Feb. 21, 2025, 4:56 p.m. EST)
Set Aside
Small Business (SBA)
Place of Performance
Hastings, MN United States
Source
SAM

Current SBA Size Standard
$19 Million
Pricing
Likely Fixed Price
Est. Level of Competition
Average
Est. Value Range
Experimental
$50,000 - $150,000 (AI estimate)
Signs of Shaping
81% of obligations for similar contracts within the Department of the Army were awarded full & open.
On 2/7/25 USACE St. Paul District issued Solicitation W912ES25Q0033 for Lock and Dam #2 Replacement of Lift Station Control Panel due 2/21/25. The opportunity was issued with a Small Business (SBA) set aside with NAICS 238210 (SBA Size Standard $19 Million) and PSC 6110.
Primary Contact
Name
Theodore Hecht   Profile
Phone
(651) 290-5415

Secondary Contact

Name
Kenneth J. Eshom   Profile
Phone
None

Documents

Posted documents for Solicitation W912ES25Q0033

Question & Answer

Incumbent or Similar Awards

Contracts Similar to Solicitation W912ES25Q0033

Potential Bidders and Partners

Awardees that have won contracts similar to Solicitation W912ES25Q0033

Similar Active Opportunities

Open contract opportunities similar to Solicitation W912ES25Q0033

Additional Details

Source Agency Hierarchy
DEPT OF DEFENSE > DEPT OF THE ARMY > USACE > MVD > W07V ENDIST ST PAUL
FPDS Organization Code
2100-W912ES
Source Organization Code
100221313
Last Updated
March 8, 2025
Last Updated By
theodore.r.hecht@usace.army.mil
Archive Date
March 8, 2025